Clinical Usefulness of the Serum Anion Gap
نویسندگان
چکیده
The anion gap in the serum is useful in the interpretation of acid-base disorders and in the diagnosis of other conditions. In the early 1980s, ion-selective electrodes for specific ionic species were introduced for the measurement of serum electrolytes. This new method has caused a shift of the anion gap from 12±4 mEq/L down 6±3 mEq/L. It is worthy for clinicians to understand the range of normal anion gap and the measuring methods for serum sodium and chloride in the laboratories that support their practice. While an increase in the anion gap is almost always caused by retained unmeasured anions, a decrease in the anion gap can be generated by multiple mechanisms.
منابع مشابه
The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?
The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However...
متن کاملIs Serum Lactate Necessary in Patients with Normal Anion Gap and Serum Bicarbonate?
INTRODUCTION There has been an increase in patients having serum lactate drawn in emergency situations. The objective of this study was to determine whether or not it was necessary to obtain a lactate level in patients with a normal serum bicarbonate level and anion gap. METHODS This is a retrospective chart review evaluation of 304 patients who had serum lactate and electrolytes measured in ...
متن کاملSerum anion gap: its uses and limitations in clinical medicine.
The serum anion gap, calculated from the electrolytes measured in the chemical laboratory, is defined as the sum of serum chloride and bicarbonate concentrations subtracted from the serum sodium concentration. This entity is used in the detection and analysis of acid-base disorders, assessment of quality control in the chemical laboratory, and detection of such disorders as multiple myeloma, br...
متن کاملAn Improvement to the Properties of GAP Binder with Energetic Ionic Liquids
Glycidyl azide polymer (GAP) is used as a binder in the propellants. Energetic ionic liquids are used as a plasticizer to correct the properties of polymer. In this study, first ionic liquid was bonded to the GAP by certain amount and then the energetic anions of nitrate (NO3) and azide (N3) were used to exchange anion. FTIR analyses confirm accurately anions exchange. DSC, viscometer and heat ...
متن کاملAnion gap, anion gap corrected for albumin, and base deficit fail to accurately diagnose clinically significant hyperlactatemia in critically ill patients.
Anion gap, anion gap corrected for serum albumin, and base deficit are often used as surrogates for measuring serum lactate. None of these surrogates is postulated to predict hyperlactatemia in the critically ill. We prospectively collected data from September 2004 through August 2005 for 1381 consecutive admissions. Patients with renal disease, ketoacidosis, or toxic ingestion were excluded. A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2006