Does ultrasound measurement improve the accuracy of electronic brachytherapy in the treatment of superficial non-melanomatous skin cancer?

نویسندگان

  • Uma Goyal
  • Junhan Pan
  • Haiyan Cui
  • Baldassarre Stea
چکیده

PURPOSE Electronic brachytherapy (eBT) is a form of contact radiation therapy used for thin superficial non-melanomatous skin cancers (NMSCs). An accurate measurement of diameter and depth is important for eBT treatment planning. Therefore, we compared clinical measurements by an experienced physician to measurements obtained using ultrasound (US), an objective imaging modality, in order to determine if clinical measurements were accurate enough for adequate NMSC treatment. MATERIAL AND METHODS Eighteen patients with 20 biopsy-proven NMSCs first had a clinical examination and then an US evaluation prior to starting eBT. One physician provided a clinical measurement for diameter and depth based on physical examination during radiation oncology consultation. The patients then had an US evaluation with a 14 or 18 MHz US unit, to determine both the diameter and depth measurements; eBT dose prescription was done using the US derived measurements. The clinical measurements and US measurements were compared using a t-test. RESULTS Seventeen lesions were basal cell carcinoma and 3 lesions were squamous cell carcinoma. The most common location was the nose (10 lesions). The difference between the clinical and the US derived measurements for the second largest diameter was found to be statistically significant (p = 0.03), while the difference for the largest diameter of the lesions was not (p = 0.24). More importantly, the depth measurements obtained with US were also found to be significantly different from the clinical estimates (p = 0.02). All patients have had a complete response to therapy with a median follow-up of 24 months. CONCLUSIONS Statistically different measurements were obtained in 2 of 3 parameters used in choosing applicator size and prescription depth using an US assessment. The data presented suggests that US is a more objective modality than clinical judgment for determining superficial NMSC diameter and prescription depth for personalized eBT planning.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A pilot study of ultrasound-guided electronic brachytherapy for skin cancer

PURPOSE Electronic brachytherapy (eBT) has gained acceptance over the past 5 years for the treatment of non-melanomatous skin cancer (NMSC). Although the prescription depth and radial margins can be chosen using clinical judgment based on visual and biopsy-derived information, we sought a more objective modality of measurement for eBT planning by using ultrasound (US) to measure superficial (< ...

متن کامل

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

Skin disease diagnosis based on tissue frequency information analysis using sonogram patterns

Abstract Background Today early detection of common cancer with modern smart calculation is the most interesting issue due to the increased chances of successful treatment. Skin cancer is a serious and dangerous complication that threatens the lives of many people and if not diagnosed in time, it will have bad consequences. It is the fifth most common cancer in the female population and...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017