Cardiopulmonary bypass for thoracic aortic aneurysm: a report on 488 cases.

نویسندگان

  • Yulong Guan
  • Jing Yang
  • Caihong Wan
  • Meiling He
  • Peiqing Dong
چکیده

Our objective was to investigate different cardiopulmonary bypass (CPB) techniques for thoracic aortic aneurysm retrospectively. Four hundred and eighty-eight patients with thoracic aortic aneurysm received surgical treatment. Total CPB was used routinely in 331 cases with ascending aortic aneurysm. When the aneurysm expanded to the aortic arch, brain protection was executed by adopting deep hypothermia circulatory arrest (DHCA) or DHCA combined with retrograde cerebral perfusion (RCP). Selected cerebral perfusion via carotid artery was used in three cases and separated upper and lower body perfusion in five cases. Left heart bypass was adopted for the surgeries of 157 cases with descending aortic aneurysm. In two of the cases, ventricular defibrillation could not be achieved, and then bypass was altered to separated upper and lower body perfusion to acquire satisfactory outcome. In the ascending aortic aneurysm group, DHCA time in the 17 patients was 10-63 minutes (mean 35.58 +/- 18.81 min), and DHCA +/- RCP time in 61 patients was 16-81 minutes (mean 43.43 +/- 17.91 min). Total mortality of aortic aneurysm surgery requiring full CPB was 5.4% (18/331), in which eight patients died in emergency operations. The total mortality of emergency operation was 11.9% (8/67). In the descending aortic aneurysm group, time of left heart bypass was 125.56 +/- 57.28 min, and the total mortality was 7% (11 of 157 patients). Three patients developed postoperative paraplegia. Techniques for extracorporeal circulation for surgery of the aorta are dependent on the nature of the disease and require a flexible approach to meet the specific anatomical challenge. The ability to alter the perfusion circuit to meet unexpected situations should be anticipated and planned for. In this series, we have varied our approach to perfusion techniques as required with acceptable outcome data as compared to the international literature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thoracic endovascular aortic repair and off-pump coronary artery bypass grafting after renal transplantation: a case report.

Twelve years after receiving a renal transplant, a 50-year-old woman developed asthmatic symptoms. Chest CT revealed a descending thoracic aortic aneurysm. She had undergone percutaneous coronary intervention to treat the left anterior descending artery 10 years earlier. Coronary artery angiography revealed restenosis of the left anterior descending artery (99%, #6 in-stent). Because cardiopulm...

متن کامل

Wrapping of an Ascending Aortic Aneurysm with the Multiple Boot-Straps Technique in a Patient Undergoing Off-Pump Coronary Artery Bypass Grafting

Ascending aortic aneurysms are usually treated with graft replacement under cardiopulmonary bypass. However, if a candidate for off-pump coronary artery bypass grafting has an enlarged ascending aorta, surgeons may consider wrapping it without cardiopulmonary bypass. Here, we report a 78-year-old female who underwent successful wrapping of the ascending aorta concomitant with off-pump coronary ...

متن کامل

Visceral Debranching Thoracic Endovascular Aneurysm Repair for Chronic Dissecting Thoracoabdominal Aortic Aneurysm

Type II chronic dissecting thoracoabdominal aortic aneurysms are a surgically challenging disease. The conventional thoracoabdominal aortic aneurysm repair technique using cardiopulmonary bypass is a high-risk procedure. However, a recently developed endovascular technique may be an alternative treatment for the disease, but faces the obstacle of lesional restriction. This new technique uses a ...

متن کامل

Two cases of off-pump coronary artery bypass grafting combined with abdominal aortic aneurysm repair.

Two cases of coronary artery disease coexisting with abdominal aortic aneurysm were treated with off-pump coronary artery bypass grafting combined with repair of the aneurysm. The first patient was a 67-year-old man exhibiting a large pulsating abdominal mass. Abdominal computed tomography demonstrated a 9-cm aneurysm and coronary angiogram revealed a 90% stenosis of the obtuse marginal branch ...

متن کامل

Hybrid arch debranching and endograft repair in a patient with a ruptured thoracic aortic aneurysm.

Recent advances in hybrid techniques of aortic arch debranching allow for the repair of thoracic aortic arch aneurysm without requiring cardiopulmonary bypass or hypothermic circulatory arrest. We describe the repair of a ruptured proximal descending thoracic aortic aneurysm, using off-pump aortic arch debranching and antegrade transaortic deployment of a thoracic endograft in an elderly patient.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2004