Purpose: Heart rate variability (HRV) is acknowledged as a useful tool to estimate autonomic function. Fast Fourier transform (FFT) and autoregressive model (AR) are used for power spectral analysis of HRV. However, there is little evidence of agreement between FFT and AR in relation to HRV following food intake in females. In the present study, we applied both FFT and AR after food intake during the follicular and luteal phases, and compared raw low-frequency (LF) and highfrequency (HF) powers, and LF/HF ratio obtained with the two power-spectral analytical methods. Methods: All subjects participated in two sessions: follicular phase session and luteal phase session. In each session, R-R intervals were continuously recorded before and after meals, and power spectral analysis of heart rate variability was performed. We analyzed low-frequency power (LF: 0.04 0.15 Hz) and high-frequency power (HF: 0.15 0.40 Hz) by using FFT and AR. LF and HF power were computed for each 30 sec, 1 min, 2.5 min, and 5 min of the 5-min R-R data before meal intake and at 20, 40, 60 and 80 min after meal intake. The LF/HF ratio was calculated as an index of sympathovagal balance. Results: In the present study, after 30 sec and 1 min of segment analysis, there was little interchangeability between AR and FFT in LF, HF, and LF/HF ratio in both follicular and luteal phases. In 2.5 min or 5 min of segment analysis, there was interchangeability between FFT and AR in LF and HF, but not in the LF/HF ratio in both follicular and luteal phases. Additionally, FFT underestimated HRV compared with AR, and the extent of underestimation increased with increasing AR value. Conclusion: FFT underestimated HRV compared with AR, and FFT correlated poorly with AR when the analysis segment was shortened. Corresponding author.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum: A comparison between Walsh and autoregressive derived parameters of heart rate variability spectra in normal subjects and diabetics.

OBJECTIVE The objective of this study is to compare the fast Walsh transform with autoregressive method for spectral analysis of heart rate variability signals based on evaluating the quantitative and dynamic differences between the results of Walsh and autoregressive analysis of heart rate variability signals for healthy patients and diabetic patients who have suffered from diabetes more than ...

متن کامل

Sports Med 2003; 33 (12): 889-919

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 889 1. Control of Heart Rate: the Autonomic Nervous System (ANS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 891 2. Methodology and Analysis of Cardiovascular Variability: Heart Rate Variability (HRV), Blood P...

متن کامل

The Deterministic Chaos in Heart Rate Variability Signal and Analysis Techniques

The heart rate variability (HRV) signal carries important information about the systems controlling the heat rate, mainly elicited by autonomic nervous system (sympathetic and parasympathetic) controls. The analysis of HRV signal with existing linear techniques based on fast Fourier transform and autoregressive model have the disadvantages of lower sensitivity and positive predictive value of <...

متن کامل

Application of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints

In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...

متن کامل

Comparison of computation time for estimation of dominant frequency of atrial electrograms: Fast fourier transform, blackman tukey, autoregressive and multiple signal classification

Dominant frequency (DF) of electrophysiological data is an effective approach to estimate the activation rate during Atrial Fibrillation (AF) and it is important to understand the pathophysiology of AF and to help select candidate sites for ablation. Frequency analysis is used to find and track DF. It is important to minimize the catheter insertion time in the atria as it contributes to the ris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016