Biomimetic phantom for cardiac diffusion MRI.
نویسندگان
چکیده
PURPOSE Diffusion magnetic resonance imaging (MRI) is increasingly used to characterize cardiac tissue microstructure, necessitating the use of physiologically relevant phantoms for methods development. Existing phantoms are generally simplistic and mostly simulate diffusion in the brain. Thus, there is a need for phantoms mimicking diffusion in cardiac tissue. MATERIALS AND METHODS A biomimetic phantom composed of hollow microfibers generated using co-electrospinning was developed to mimic myocardial diffusion properties and fiber and sheet orientations. Diffusion tensor imaging was carried out at monthly intervals over 4 months at 9.4T. 3D fiber tracking was performed using the phantom and compared with fiber tracking in an ex vivo rat heart. RESULTS The mean apparent diffusion coefficient and fractional anisotropy of the phantom remained stable over the 4-month period, with mean values of 7.53 ± 0.16 × 10(-4) mm(2) /s and 0.388 ± 0.007, respectively. Fiber tracking of the 1st and 3rd eigenvectors generated analogous results to the fiber and sheet-normal direction respectively, found in the left ventricular myocardium. CONCLUSION A biomimetic phantom simulating diffusion in the heart was designed and built. This could aid development and validation of novel diffusion MRI methods for investigating cardiac microstructure, decrease the number of animals and patients needed for methods development, and improve quality control in longitudinal and multicenter cardiac diffusion MRI studies.
منابع مشابه
Standardized phantoms for quantitative cardiac MRI
Background Quantitative MR relaxometry techniques are increasingly used in cardiac MR applications, e.g. MOLLI for high resolution T1 mapping. To use these techniques in the clinic, we must understand how to make comparable measurements across vendor systems and software versions and compare results across sites. A standardized phantom used for regular quality control is one approach. The Bioma...
متن کاملRegularized Iterative Reconstruction in Tensor Tomography Using Gradient Constraints
This paper investigates the iterative reconstruction of tensor fields in diffusion tensor magnetic resonance imaging (MRI). The gradient constraints on eigenvalue and tensor component images of the diffusion tensor were exploited. A computer-generated phantom was used in order to simulate the diffusion tensor in a cardiac MRI study with a diffusion model that depends on the fiber structure of t...
متن کاملNovel anisotropic MRI diffusion phantom
Diffusion MRI (DMRI) comprises a growing list of methods, and with that the need for a reliable and robust MRI phantom with which one can calibrate and validate them. In this study we developed a novel anisotropic diffusion MRI phantom and demonstrated its applicability by producing fractional anisotropy (FA) maps derived from DTI and average pore diameter maps using double Pulsed Field Gradien...
متن کاملCardiac diffusion MRI without motion effects.
We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than ...
متن کاملP27 Calibrating d-PFG Filtered MRI Using a Novel Anisotropic Diffusion Phantom
Diffusion Phantom Michal Komlosh 1, Evren Ozarslan 1, Martin Lizak 1, Ferenc Horkay 1, Peter Basser 1 1 National Institute of Health Introduction: Diffusion MRI methods can provide valuable microstructural in formation about tissues and porous media within an imaging volume [1-3], how ever, calibrating them is problematic owing to the lack of suitable anisotropic diffusion MRI phantoms. Here ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 43 3 شماره