Ipsilateral pedicle screw placement with contralateral percutaneous facet screws: Early results with an alternative in lumbar arthrodesis
نویسندگان
چکیده
Correspondence: Richard Rhiew Department of Neurosurgery, 39 Wood St., Mansfi eld, OH 44906, USA Tel +1 419 522 2472 Fax +1 419 774 1300 Email [email protected] Abstract: Transforaminal lumbar interbody fusion (TLIF) is a widely used method of surgical treatment for a variety of lumbar spinal disorders. Bilateral transpedicular instrumentation is routinely used in conjunction with an interbody graft to provide additional stability. In this technical note, we describe our fusion construct using ipsilateral pedicle screw placement on the side of TLIF and contralateral facet screw placement. We performed this construct at six levels in four patients. Suggested advantages include: low morbidity, small incision and lower cost. Outcomes parameters included radiographic evidence of solid union at four months and improvement in Oswestry Disability Index. A mean improvement from a preoperative score of 73 to 26 after surgery was observed at one-year follow-up. There were no instrument-related complications. In conclusion, this hybrid screw system minimizes contralateral dissection and is an attractive alternative to standard bilateral pedicle screw fi xation.
منابع مشابه
Mini-open or percutaneous bilateral lumbar transfacet pedicle screw fixation: a technical note.
STUDY DESIGN Case report. OBJECTIVE To describe the technique used to place bilateral lumbar transfacet pedicle screws. SUMMARY OF BACKGROUND DATA Transfacet pedicle screw fixation is a growing alternative and biomechanically comparable with traditional pedicle screw fixation. There is no clear description of technique steps for placing transfacet pedicle screws available in the literature,...
متن کاملTranslaminar Facet Screw Fixation
Introduction Lumbar fusion has proven to be an accepted treatment for a variety of indications. Pedicle screw fixation has historically been the gold standard for providing stabilization to the lumbar motion segment while the fusion matures. However, numerous studies have reported high complication rates, increased pain, and juxtalevel degeneration due to the size of the pedicle screw instrumen...
متن کاملComparison of superior-level facet joint violations during open and percutaneous pedicle screw placement.
BACKGROUND Superior-level facet joint violation by pedicle screws may result in increased stress to the level above the instrumentation and may contribute to adjacent segment disease. Previous studies have evaluated facet joint violations in open or percutaneous screw cases, but there are no reports describing a direct institutional comparison. OBJECTIVE To compare the incidence of superior-l...
متن کاملComparison of Cranial Facet Joint Violation Rate Between Percutaneous and Open Pedicle Screw Placement
Percutaneous and open pedicle screw placements have been widely used in lumbar fusion surgery. However, there are conflicting reports of cranial facet joint violation rate for the 2 techniques. To better determine the rate of cranial facet joint violation, a systematic review and meta-analysis was performed in the present study. We searched the established electronic literature databases includ...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009