Feasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles

نویسندگان

  • Menahem Y. Rotenberg
  • Hovav Gabay
  • Yoram Etzion
  • Smadar Cohen
چکیده

A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-injected magnetic microparticles in the right ventricular cavity using an external electromagnet, the application of magnetic pulses generates mechanical stimulation that provokes ventricular overdrive pacing in the rat heart. This temporary pacing consistently managed to revert drug-induced bradycardia, but could only last up to several seconds in the rat model, most likely due to escape of the particles between the applied pulses using our current experimental setting. In a pig model with open chest, MEF-based pacing was induced by banging magnetic particles and has lasted for a longer time. Due to overheating of the electromagnet, we intentionally terminated the experiments after 2 min. Our results demonstrate for the first time the feasibility of external leadless temporary pacing, using injectable magnetic microparticles that are manipulated by an external electromagnet. This new approach can have important utilities in clinical settings in which immediate and painless control of cardiac rhythm is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrieval of the Leadless Cardiac Pacemaker

Leadless cardiac pacemakers (LPs) have emerged as a safe and effective alternative to conventional transvenous pacemakers for patients with an indication for single-chamber ventricular pacing. In 2 prospective studies with intermediate follow-up, leadless pacemakers exhibited high acute implantation success rates and stable pacing performance at 6 months. Despite these promising results, the ab...

متن کامل

State of the art of leadless pacing.

Despite undisputable benefits, conventional pacemaker therapy is associated with specific complications related to the subcutaneous device and the transvenous leads. Recently, two miniaturized leadless pacemakers, Nanostim™ (St. Jude Medical) and Micra™ (Medtronic), which can be completely implanted inside the right ventricle using steerable delivery systems, entered clinical application. The W...

متن کامل

ECGs and Pacemakers

Leadless pacemakers will most likely be the future of cardiac pacing. Leadless pacing employs a singlechamber system to pace only the right ventricle and is fully self-contained, which eliminates the need for leads. These systems, implanted by using a transcatheter sheath, are indicated for patients who need right ventricular pacing only. These devices enable patients to avoid lead-related comp...

متن کامل

Recent Advances in Pacing and Defibrillation

Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ...

متن کامل

Successful percutaneous retrieval of a leadless pacemaker due to an acute rise in pacing threshold

Leadless cardiac pacemakers (LCP) have become available recently. Both its acute and long-term performance in a large population of patients remain to be tested. Subacute rise in pacing threshold has been reported as an uncommon complication. On the other hand, the retrieval technique for LCP with passive fixation mechanism has not been previously described in details. Herein we report a newly ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016