Comparison of the performance of microtube column systems and solid-phase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies.
نویسندگان
چکیده
To compare the performance of seven currently available test systems in the detection of erythrocyte alloantibodies (ab), we tested in parallel 446 sera samples containing red cell ab [368 sera samples with ab that are assumed to be clinically significant (cs-ab) and 78 sera samples with ab that are assumed to be of minor clinical significance (ms-ab)] using the tube spin low-ionic-strength solution (addition method) indirect antiglobulin test (tube LISS-IAT), three microtube column agglutination techniques (DiaMed-ID, Ortho BioVue and Bio-Rad Scangel), one affinity adherence test system (CLB/Mast CellBind Screen) and two solid-phase tests [Biotest Solidscreen II and Immucor Capture-R Ready-Screen (4)]. To address the specificity of the three test systems under routine conditions, results of 4566 patient samples obtained using the tube LISS-IAT, results of 5205 patient samples obtained using the Scangel and results of 3560 samples obtained using the Capture-R were evaluated. The DiaMed-ID detected 344 cs-ab and 43 ms-ab, BioVue 333 cs-ab and 48 ms-ab, Scangel 348 cs-ab and 62 ms-ab, CellBind Screen 346 cs-ab and 47 ms-ab, Solidscreen 330 cs-ab and 38 ms-ab, Capture-R 358 cs-ab and 45 ms-ab and LISS-IAT 159 cs-ab and 12 ms-ab. In routine practice, erythrocyte cs-ab could be identified in 61 (67.8%) of 90 reactive sera (specificity: 98.6%) in the tube LISS-IAT, in 169 (58.7%) of 288 (94.4%) in Bio-Rad Scangel and in 101 (51.0%) of 198 reactive sera (94.3%) in Capture-R. We conclude that the sensitivity of the microcolumn, affinity adherence and solid-phase test systems in the detection of cs-ab was similar and was markedly superior to that of the conventional tube LISS-IAT. All high-sensitive test systems produced higher rates of false positives and ms-ab compared to the tube test. An individual cost-benefit analysis, considering the recent knowledge about the clinical significance of weak-reactive cs-ab, should be performed in every institution to decide whether and if so which high-sensitive screening system should be applied.
منابع مشابه
SENSITIBITY OF VARIOUS METHODS IN THE DETECTION OF IgG ANTIBODIES TO RED CELL ANTIGENS
In recent years, new methods such as microtube column agglutination methods and microplate methods using automated instruments have been used for blood typing, antibody screening testing and crossmatching testing. However, no precise comparison study of the performance of these methods and conventional tube methods has been done. In the present study, we performed a comparison study on sensitiv...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملPrevalence of Alloantibodies and Autoantibodies in Transfusion Dependent Thalassemia Patients
Background: The development of anti-red blood cell alloantibodies remains a major problem in transfusion of blood in thalassemia major patients. Also, Autoantibodies can result in clinical hemolysis and difficulty in cross-matching blood. We studied the frequency of red blood cell alloimmunization and autoimmunization among thalassemia patients who received regular transfusions in Ilam province...
متن کاملFrequencies and Specificities of “Enzyme-Only” Detected Erythrocyte Alloantibodies in Patients Hospitalized in Austria: Is an Enzyme Test Required for Routine Red Blood Cell Antibody Screening?
UNLABELLED The aim of this study was to determine the frequencies and specificities of "enzyme-only" detected red blood cell (RBC) alloantibodies in the routine antibody screening and antibody identification in patients hospitalized in Austria. Routine blood samples of 2420 patients were investigated. The antibody screening was performed with a 3-cell panel in the low-ionic strength saline- (LI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transfusion medicine
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2006