Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound.

نویسندگان

  • Alexander W Leber
  • Andreas Knez
  • Alexander Becker
  • Christoph Becker
  • Franz von Ziegler
  • Konstantin Nikolaou
  • Carsten Rist
  • Maximilian Reiser
  • Carl White
  • Gerhard Steinbeck
  • Peter Boekstegers
چکیده

OBJECTIVES We evaluated the accuracy of contrast-enhanced multidetector spiral computed tomography (MDCT) for the noninvasive detection and classification of coronary plaques and compared it with intracoronary ultrasound (ICUS). BACKGROUND Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification and to monitor progression of coronary atherosclerosis. METHODS We included 46 consecutive patients with a distinctive risk profile, who were investigated by ICUS (Goldvision, 20 MHz, Jomed Inc., Rancho Cordova, California). Due to the inability to slow the heart rate below 65 beats/min (n = 7) and due to renal insufficiency (n = 2), nine of 46 consecutive patients could not be studied by MDCT (Sensation 16, Siemens, Forchheim, Germany). RESULTS In the remaining 37 patients, 68 vessels were investigated by ICUS, and 58 of these vessels were visualized by MDCT with image quality sufficient for analysis. In these vessels that were divided in 3-mm sections, MDCT correctly classified 62 of 80 (78%) sections containing hypoechoic plaque areas, 87 of 112 (78%) sections containing hyperechoic plaque areas, and 150 of 158 (95%) sections containing calcified plaque tissue. In 484 of 525 (92%) sections, atherosclerotic lesions were correctly excluded. The MDCT-derived density measurements within coronary lesions revealed significantly different values for hypoechoic (49 HU [Hounsfield Units] +/- 22), hyperechoic (91 HU +/- 22), and calcified plaques (391 HU +/- 156, p < 0.02). CONCLUSIONS This study demonstrates that, in the case of diagnostic image quality, contrast-enhanced MDCT permits an accurate identification of coronary plaques and that computed tomography density values measured within plaques reflect echogenity and plaque composition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved atrial mechanical efficiency during alternate- and multiple-site atrial pacing compared with conventional right atrial appendage pacing: implications for selective site pacing to prevent atrial fibrillation.

1. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002;106:2051–4. 2. Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 2...

متن کامل

Left ventricular pseudoaneurysm as a late complication of mitral annuloplasty.

Theessen H, Karakaya M, Daniel WG, Bautz W, Kalender WA, Anders K. Contrast-enhanced coronary artery visualization by dual-source computed tomography–initial experience. Eur J Radiol 2006;57:331–335. 9. Johnson TR, Nikolaou K, Wintersperger BJ, Leber AW, von Ziegler F, Rist C, Buhmann S, Knez A, Reiser MF, Becker CR. Dual-source CT cardiac imaging: initial experience. Eur Radiol 2006;16:1409–14...

متن کامل

Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.

The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of...

متن کامل

Assessment of Non-Calcified Coronary Plaques Using 64-Slice Computed Tomography: Comparison With Intravascular Ultrasound

BACKGROUND AND OBJECTIVES Non-invasive detection and characterization of plaque composition may constitute an important step in risk stratification and monitoring of the progression of coronary atherosclerosis. Multislice computed tomography (MSCT) allows for accurate, non-invasive detection and characterization of atherosclerotic plaques, as well as determination of coronary artery stenosis. T...

متن کامل

Characterization of coronary atherosclerotic plaques by multidetector computed tomography.

Multidetector computed tomography (MDCT) provides 3-dimensional noninvasive visualization of the coronary arterial tree. We compared MDCT with intravascular ultrasound (IVUS) for assessment of severity of coronary artery stenosis and composition of atherosclerotic plaques in 40 patients (32 men; mean age 52 years, range 33 to 86) with documented coronary artery disease. Cross-sectional images o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 2004