Analysis of "Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial".
نویسنده
چکیده
In an article in Journal of Diabetes Science and Technology, Halldorsdottir and coauthors examined the accuracy of five blood glucose monitoring systems (BGMSs) in a study sponsored by the manufacturer of the BGMS CONTOUR NEXT EZ (EZ) and found that this BGMS was the most accurate one. However, their findings must be viewed critically given that one of the BGMSs (ACCU-CHEK Aviva) was not compared against the reference measurement specified by its manufacturer, thus making it likely that it performed suboptimally. Also, the accuracy of the glucose-oxidase-based ONE TOUCH Ultra2 and TRUEtrack BGMS is likely to have been underestimated because of the expected low oxygen level in the glycolysed blood samples used to test the performance of these BGMSs under hypoglycemic conditions. In conclusion, although this study shows that EZ is an accurate BGMS, comparisons between this and other BGMSs should be interpreted with caution.
منابع مشابه
Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.
BACKGROUND This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. METHODS Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject wa...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملElectromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors
Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...
متن کاملCan the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...
متن کاملEvaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method
Abstract Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2013