Nonspecific reactions in the hemagglutination inhibition test for detection of rubella antibodies.

نویسندگان

  • D B Budzko
  • D F Jelinek
  • B W Wilcke
چکیده

Approximately 7% of the sera tested to determine the presence of rubella-specific antibodies by the hemagglutination inhibition test demonstrated abnormal patterns of reactivity, rendering the test unreadable. Another 3% of sera were shown to have false-positive titers as high as 1:128. When these abnormally reacting and false-positive sera were heated at 56 degrees C for 30 min after chemical treatment they always converted to negative, indicating the absence of specific rubella hemagglutination-inhibiting antibody. These results were confirmed by fractionation of the sera after sucrose gradient centrifugation. It was established that manifestation of these nonspecific results was dependent on the concentration of Ca2+ or Mn2+. The heat-labile inhibitor(s) responsible for abnormal and false-positive reactions was found not to be complement. This inhibitor(s) was detected in the light fractions of sera and when added to negative sera was capable of reproducing the abnormal patterns of reactivity. These results emphasize the necessity of heating sera for the rubella hemagglutination inhibition test after the chemical removal of nonspecific inhibitors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rubella hemagglutination-inhibition test: false-positive reactions in sera contaminated with bacteria.

We have shown that bacterial contamination of sera can have a marked influence on the results of the rubella hemagglutination-inhibition (HI) test. In addition to increasing the levels of nonspecific agglutinins, a number of common bacterial species tested had a significant effect on the HI titers. When sera free from rubella-specific antibodies were contaminated with Bacillus subtilis or Pseud...

متن کامل

Specificity of the passive hemagglutination test for antibody to rubella virus and the passive hemagglutination response after vaccination.

Nonspecific reactions by the passive hemagglutination test for rubella viral antibody occurred with 1.5% of sera tested. Rises in passive hemagglutination titers (greater than or equal to 4X) occurred with some serum samples taken 14 days after vaccination.

متن کامل

Rubella hemagglutination inhibition: removal of nonspecific agglutination due to manganous chloride.

Nonspecific inhibitors of rubella hemagglutination can be removed by treatment of sera with heparin-manganous chloride for use in the hemagglutination-inhibition test. After removal of nonspecific inhibitors by this procedure, an excess of manganous chloride may remain. This may cause the cells to agglutinate, thus obscuring the reading at low serum dilutions. This disadvantage can be overcome ...

متن کامل

Comparison of the latex agglutination test with the hemagglutination inhibition test, enzyme-linked immunosorbent assay, and neutralization test for detection of antibodies to rubella virus.

The ability of a rapid, latex agglutination test to diagnose rubella infection and to measure immune status was evaluated by comparison with the hemagglutination-inhibition (HAI) test, enzyme-linked immunosorbent assay (ELISA), and the neutralization (NT) test. The latex agglutination test accurately detected serological conversions in 74 pairs of sera representing 21 natural infections and 53 ...

متن کامل

Evaluation of a Latex Agglutination Test for Detection of Antibodies to Rubella Virus in Selected Sera

A new latex agglutination test for rubella virus was used to test sera with a hemagglutination inhibition titer of -8 (97 specimens) or >256 (158 specimens). Maximum latex agglutination test sensitivity was achieved when low-titer sera were tested undiluted and high-titer sera were diluted (1:10). A modification of the protocol of the manufacturer resulted in a latex agglutination-hemagglutinat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1981