Use of a Laser-equipped Centrifugal Analyzer for Kinetic Measurement of Serum lgG
نویسندگان
چکیده
Use of a visible laser in an Aminco “Rotochem” centrifugal analyzer enables light-scattering measurements to be made with this instrument. The modification is technically simple, inexpensive, and requires no fundamental changes in basic instrument design. The laser-modified analyzer has been applied to the measurement of lgG in serum. A two-point kinetic analysis is used to quantitate lgG from a standard curve: protein concentration vs. change in intensity of the scattered light during a fixed time interval. Fourteen 20-tI samples can be simultaneously determined in 1.9 mm. No sample blank corrections are required. Within-run precision studies, based in each case on 56 replicate measurements, yielded coefficients of variation of 3.8 % and 4.8 % for normal and abnormal pools, respectively.
منابع مشابه
Measurement of total protein and albumin in serum with a centrifugal analyzer.
In most clinical chemistry laboratories, mechanized procedures are essential for measurement of serum total protein and albumin. The biuret reaction is well established as the most practical approach to mechanized total protein measurements (1-4); albumin has posed a more difficult problem, with several procedures being proposed, some of which have involved salt fractionation (1-4), electrophor...
متن کاملNew kinetic method for creatinine measurement now automated in the Cobas Fara centrifugal analyzer.
A new kinetic method to determine creatimne in serum by using an alkaline 3,5-dinitrobenzoate solution was recently reported (1). Interference from pseudo-creatinine chromogens, bilirubin, or triacylglycerols was negligible. The results obtained with this kinetic spectrophotometric assay, performed with an Eppendorf ACP 5040 analyzer, agreed well with the procedure of Jaff#{233}, as modified by...
متن کاملEvaluation of kinetic light scattering as an approach to the measurement of specific proteins with the centrifugal analyzer. I. Methodology.
A laser-modified centrifugal analyzer was used to develop kinetic light scattering methods for the measurement of human immunoglobulins IgG, IgA, and IgM. Comparison of equilibrium light scattering methods with kinetic procedures for IgG and IgA demonstrate equivalent precision and relative accuracy. However, quantitative results obtained by equilibrium and kinetics methods for IgM were found t...
متن کاملNew kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.
A procedure has been developed for the automated measurement of conjugated bilirubin in serum with a centrifugal analyzer. The conjugated bilirubin is measured by a fixed time kinetic method which monitors the reaction between conjugated bilirubin and diazotized sulfanilic acid at 550 nm. Results are calculated based on a comparison of the reagent blank-corrected absorbance changes between 15 s...
متن کاملSerum alkaline phosphatase: total activity and isoenzyme determinations made by use of the centrifugal fast analyzer.
We present a kinetic method in which the centrifugal analyzer is used to determine total alkaline phosphatase activity and to measure the isoenzymes in bone, liver, and the L-phenylalanine-sensitive fraction (intestine, tumor, and placenta). Measurements were made at 30#{176}C in diethanolamine buffer, with p-nitrophenylphosphate as substrate. The a!kaline phosphatase isoenzymes were separated ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004