Microbiological safety and cost-effectiveness of weekly breathing circuit changes in combination with heat moisture exchange filters: a prospective longitudinal clinical survey

نویسندگان

  • Nils-Olaf Hübner
  • Georg Daeschlein
  • Christian Lehmann
  • Sergei Musatkin
  • Ute Kohlheim
  • Andreas Gibb
  • Ojan Assadian
  • Hiroyoshi Kobayashi
چکیده

AIM To assess the safety and cost effectiveness of a usage for seven days of breathing circuit systems (BCSs) in combination with heat moisture exchanger filters (HMEF) in operation room anesthesia. METHOD In a prospective longitudinal clinical study, the contamination on high-risk surfaces (HMEF together with inner and outer surface of BCS) was monitored over 1, 2, 5, and 7 days. RESULTS of endogenous respiratory patient flora and contamination flora of BCS, HMEF and bag were compared. Costs of prolonged use of BCS together with HMEF up to 7 days were calculated. RESULTS Neither physiological respiratory flora nor colonizing pathogens of the oropharynx of the ventilated patients were transmitted through the filters at any time. None of the included patients developed a postoperative pneumonia. Using the BCS for 24 hours provides a cost savings of up to 40% versus single use. Extending the change interval from 24 hours to 48 hours saved over 50% compared to change after each patient, and an additional 19% compared to change after 24 hours. In combination with a HMEF BCS can be used up to 7 days without clinical risk on multiple patients in operation room settings. CONCLUSION Expanding the usage of berating in combination with usage of moist exchange filters is feasible, microbiologically safe and cost effective, as 41% of material costs per ventilation may be saved. Further research is needed to confirm these results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A breathing filter exchanging heat and moisture prevents asthma induced by cold air.

In order to devise a protective aid against bronchial obstruction induced by cold air, we have tested a breathing filter with heat and moisture exchanging properties. Nine asthma patients, who all had a history of cold-induced asthma, took part in exercise tests on an ergometer bicycle at a temperature of approximately -10 degrees C, without and with a breathing filter. Without a breathing filt...

متن کامل

The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial

BACKGROUND During anesthesia, as compared with intensive care, the time of the tracheal intubation is much shorter. An inhaled gas minimum humidity of 20 mgH2O.L-1 is recommended to reduce the deleterious effects of dry gas on the airways during anesthesia with tracheal intubation. The Fabius GS Premium® anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat ga...

متن کامل

Panel Discussion: Filtration of breathing gases during mechanical ventilation

Filtration of contaminated breathing gases is a necessary measure in mechanical ventilation. There are two types of filters available for filtration of breathing gases: mechanical filters and electrostatic filters. Filter efficiency can be established through a number of means, the most stringent being the High Efficiency Particulate Air (HEPA) test. While a variety of HEPA-grade filters are av...

متن کامل

Adsorption of desflurane by the silica gel filters in breathing circuits: an in vitro study

BACKGROUND During general anesthesia, a heated breathing circuit (HBC) is used to replace the heat and moisture exchange function of the upper airway. One HBC uses an air dryer filter that employs silica gel (SG) as a desiccant. SG is capable of adsorbing many organic compounds. Therefore, we undertook an in vitro study of the adsorption of desflurane by SG filters. METHODS An HBC was connect...

متن کامل

The Impact of rainwater harvesting systems in increasing the soil moisture in soil profile of Ahram rainfed gardens in Bushehr province

Integrated methods to store precipitation when it is not sufficient to cause floods will provide suitable conditions for improving the vegetation of floodplains. In this study, the application of rainwater harvesting systems in combination with the performance of flood distribution networks and its impact on increasing the moisture storage in soil profile were investigated. Therefore, while usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011