A high-accuracy universal polarimeter study of optical anisotropy and optical activity in laminated collagen membranes.
نویسندگان
چکیده
A novel method for fabricating anisotropic collagen membranes, which regulate the preferred orientation, is developed. The high-accuracy universal polarimeter (HAUP) method is used for simultaneous and quantitative evaluations of the optical anisotropy and optical activity. The evaluation of these optical quantities, enabled by the HAUP method, is beneficial to the field of tissue engineering.
منابع مشابه
Optical Activity and Optical Anisotropy in Photomechanical Crystals of Chiral Salicylidenephenylethylamines.
Introducing chirality into photomechanical crystals is beneficial for the diversification of mechanical motion. Measurement of the chiroptical and optical anisotropic properties of chiral crystals is indispensable for evaluating photomechanical crystals. The platelike crystals of S- and R-enantiomers of photochromic N-3,5-di-tert-butylsalicylidene-1-phenylethylamine in enol form (enol-(S)-1 and...
متن کاملThe Effect of Trifluoroethanol and Glycerol on the Thermal Properties of Collagen Using Optical Displacement-Enhanced Heterodyne Polarimeter
An angular displacement-enhanced heterodyne polarimeter has been employed to investigate the interplay between trifluoroethanol (TFE) and glycerol on the thermal denaturation of type I collagen. The concentration of the collagen solution was fixed at 0.341 (mg/mL), and was heated from 25 °C to 55 °C. TFE solutions with concentrations of 5%, 10%, 15%, 20%, 40% and 80% (v/v) were prepared and the...
متن کاملTheoretical study of magnetic susceptibility and optical activity of small molecules containing one chiral center
In the first part of this work, correlation between optical activity and elements of magnetic susceptibility tensor (MST) for five classes of model small molecules containing a single chiral center has been studied using quantum computational techniques at DFT-B3LYP level of theory with 6-311G basis set. Several molecular properties are used to reduce the MST elements prior to the examination o...
متن کاملSelf-referenced, microdegree, optical rotation polarimeter for biomedical applications: an analysis.
We comprehensively analyze the performance of a type of optical rotation (OR) polarimeter, which has been designed from the outset to fit the special requirements of two major applications: general chiral detection during the separation of optical isomers by high-pressure liquid chromatography systems in the pharmaceutical industry, and monitoring of glucose in the interstitial fluid of diabeti...
متن کاملEngineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)
Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chemical communications
دوره 50 95 شماره
صفحات -
تاریخ انتشار 2014