Extended coherence length megahertz FDML and its application for anterior segment imaging
نویسندگان
چکیده
We present a 1300 nm Fourier domain mode locked (FDML) laser for optical coherence tomography (OCT) that combines both, a high 1.6 MHz wavelength sweep rate and an ultra-long instantaneous coherence length for rapid volumetric deep field imaging. By reducing the dispersion in the fiber delay line of the FDML laser, the instantaneous coherence length and hence the available imaging range is approximately quadrupled compared to previously published MHz-FDML setups, the imaging speed is increased by a factor of 16 compared to previous extended coherence length results. We present a detailed characterization of the FDML laser performance. We demonstrate for the first time MHz-OCT imaging of the anterior segment of the human eye. The OCT system provides enough imaging depth to cover the whole range from the top surface of the cornea down to the crystalline lens.
منابع مشابه
Extended coherence length Fourier domain mode locked lasers at 1310 nm.
Fourier domain mode locked (FDML) lasers are excellent tunable laser sources for frequency domain optical coherence tomography (FD-OCT) systems due to their combination of high sweep rates, large tuning ranges, and high output powers. However, conventional FDML lasers provide coherence lengths of only 4-10 mm, limiting their use in demanding applications such as intravascular OCT where coherenc...
متن کاملCoherence length extension of Fourier domain mode locked lasers
Fourier domain mode locked (FDML) lasers provide high sweep rates, broad tuning ranges, and high output powers for optical coherence tomography (OCT) systems. However, presently-known FDML lasers at 1300 nm have relatively short coherence lengths, limiting the size of samples that can be imaged. Furthermore, FDML lasers produce only one useable sweep direction. We report FDML coherence length e...
متن کاملAnterior-segment imaging for assessment of glaucoma.
This article summarizes the physics, technology and clinical application of ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT) for assessment of the anterior segment in glaucoma. UBM systems use frequencies ranging from approximately 35 to 80 MHz, as compared with typical 10-MHz systems used for general-purpose ophthalmic imaging. OCT systems use low-coherence, near-infrared ...
متن کاملDispersion, coherence and noise of Fourier domain mode locked lasers.
We report on the effect of chromatic dispersion on coherence length and noise of Fourier Domain Mode Locked (FDML) lasers. An FDML laser with a sweep range of 100 nm around 1550 nm has been investigated. Cavity configurations with and without dispersion compensation have been analyzed using different widths of the intra-cavity optical band-pass filter. The measurements are compared to non-FDML ...
متن کاملChanging Trends of Imaging in Angle Closure Evaluation
Primary angle closure glaucoma (PACG) is a significant cause of visual disability worldwide. It predominantly affects the Eastern and South Asian population of the world. Early detection of anatomically narrow angles is important, and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). Gonioscopy has given way to modern day i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2012