Programming an optimal atrioventricular interval in a dual chamber pacemaker regional population.
نویسندگان
چکیده
BACKGROUND Since the introduction of the dual chamber pacemaker (DDDR) in the early 1980s, researchers have repeatedly discussed and attempted to optimize the atrioventricular (AV) interval, in order to increase the cardiac performance of pacemaker patients. Nominal AV delay in a DDDR is not, by hemodynamics, the best option for the majority of patients with AV conduction disorders. Our research is suggesting a simplified approach to define an optimal AV delay in a DDDR pacemaker population on the use of the programming electrocardiogram (ECG) at follow-up. METHODS The study enrolled 55 consecutive patients (67.28 ± 1.03 years, 36 male) with an initial dual chamber pacemaker implanted for complete and second degree AV block between 2005-2010. Optimal AV delay was achieved by programming an additional delay of 95 ms, to the medium value of the interval between atrial pacing spike to the end of P wave or to the width of intrinsic P wave, on the ECG of the programming device. At discharge, shortly after the implant procedure, the patients were examined by Doppler echocardiography, during nominal and optimal AV delay pacing measuring systolic and diastolic left ventricular function parameters. RESULTS Compared with the nominal AV delay settings, the left ventricular end diastolic volume did not changed (from 112.3 ± 2.3 ml to 112.9 ± 2.3 ml), the end systolic volume decreased (from 59.8 ± 1.7 ml to 50.9 ± 1.3 ml, p<0.01) after adjusted the AV delay, followed by an increased left ventricle ejection fraction (from 61.07 ± 0.18 % to 65.46 ± 0.13 %, p<0.001) and isovolumic relaxation time decreased (from 102.7 ± 1.9 ms to 97 ± 2 ms, p<0.05). E wave velocity, A wave velocity and E/A ratio were not significantly changed. CONCLUSION AV delay adjusted by programmer ECG in a follow-up session of an implantable device is a simple and useful method used in our laboratory as a resource for ventricular pacing optimization and hemodynamic improvement in patients with a dual chamber pacemaker (DDDR).
منابع مشابه
Pseudofusion in a dual chamber pacemaker: Is this pacemaker working properly?
A 57-year-old womanwith a history of dizziness due to episodes of complete heart block and bradycardia was referred to the electrophysiology ward for pacemaker implantation. A dual chamber pacemaker (Medtronic, Relia, Medtronic, Minneapolis, USA) was implanted. Its analysis showed normal function (atrial lead capture threshold 0.5 V at 0.4 ms, ventricular lead capture threshold 0.75 V at 0.4 ms...
متن کاملUtilization of Electrocardiographic P-wave Duration for AV Interval Optimization in Dual-Chamber Pacemakers
BACKGROUND Empiric programming of the atrio-ventricular (AV) delay is commonly performed during pacemaker implantation. Transmitral flow assessment by Doppler echocardiography can be used to find the optimal AV delay by Ritter's method, but this cannot easily be performed during pacemaker implantation. We sought to determine a non-invasive surrogate for this assessment. Since electrocardiograph...
متن کاملSingle-chamber versus dual-chamber pacing for high-grade atrioventricular block.
BACKGROUND In the treatment of atrioventricular block, dual-chamber cardiac pacing is thought to confer a clinical benefit as compared with single-chamber ventricular pacing, but the supporting evidence is mainly from retrospective studies. Uncertainty persists regarding the true benefits of dual-chamber pacing, particularly in the elderly, in whom it is used less often than in younger patients...
متن کاملLong-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction
PURPOSE The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS The baseline characteristic...
متن کاملOptimizing the Atrioventricular Delay in Dual Chamber Pacemakers; Is It Worth?
Submit Manuscript | http://medcraveonline.com Abbreviations: AV: Atrio-Ventricular; AVD: Atrio-Ventricular Delay; AVI: Atrio-Ventricular Interval; CO: Cardiac Output; CRT: Cardiac Resynchronization Therapy; DDD: Dual Chamber Pacemaker with Dual Pacing-Dual Sensing-Dual Response to Heart Rate; ECG: Electrocardiogram; EF: Ejection Fraction; IQR: Interquartile Range; LA: Left Atrium; LAP: Left Atr...