Local compression patterns beneath pneumatic tourniquets applied to arms and thighs of human cadavera.

نویسندگان

  • A R Hargens
  • A G McClure
  • M J Skyhar
  • R L Lieber
  • D H Gershuni
  • W H Akeson
چکیده

Distributions of tissue fluid pressure were examined beneath a standard pneumatic tourniquet in six upper extremities and six lower extremities of fresh human cadavera, disarticulated at the shoulder and hip, respectively. A standard 8-cm-wide tourniquet cuff was applied at mid-humerus or mid-femur position. Tissue fluid pressures were measured by 100-cm-long slit catheters inserted parallel to the bone at four tissue depths: subcutaneous, subfascial, mid-muscle, and adjacent to bone. All arms and thighs were studied at the following cuff pressures: 100, 150, 200, 250, 300, 400, and 500 mm Hg. Tissue fluid pressure was always maximal in subcutaneous tissue at mid-cuff. Transmission of cuff pressures to deeper tissues was significantly less (p less than 0.01) in the thighs with a girth of 40-52 cm than in the arms with a girth of 22-33 cm. At the four tissue depths studied, tissue fluid pressures fell steeply in a longitudinal direction near the cuff edge to levels near zero at points 1-2 cm outside each cuff edge. Our results suggest that wider cuffs are required on thighs than on arms to provide a bloodless field during limb surgery and to minimize underlying tissue injury associated with high cuff pressures. Our recommendation for wider tourniquet cuffs than those presently used during orthopaedic surgery is contrary to recent prevailing knowledge.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of hazardous pressure levels and gradients produced on human limbs by non-pneumatic tourniquets

This paper reports on existing and novel transducers for improved quantitative investigations of the levels of applied pressures and pressure gradients produced on human limbs by non-pneumatic tourniquet straps, and by non-pneumatic elastic bandages and elastic rolls when used as tourniquets, for comparison to benchmark data for pneumatic tourniquet cuffs commonly used in surgery at present.

متن کامل

The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.

Use of the lowest possible cuff inflation pressure should minimize the pathogenic effects of compression beneath the pneumatic tourniquet. Curved tourniquets (designed to fit conically shaped limbs) and wider tourniquets were associated with significantly lower arterial occlusion pressure (AOP) than standard, straight tourniquets on the arms and legs of 26 normal volunteers. These tourniquets w...

متن کامل

The effect of pneumatic tourniquets on the ultrastructure of skeletal muscle.

Experiments have been carried out on rhesus monkeys to determine the effect of the application of a pneumatic tourniquet on the ultrastructure of the muscles of the lower limb. Tourniquets were applied for periods lasting between one and five hours. The changes in the muscle lying immediately under the cuff of the tourniquet were more marked than those observed in muscle distal to the cuff. Thr...

متن کامل

The effect of tourniquet padding on the efficiency of tourniquets of the upper limb.

We report the effect of padding on the efficiency of the pneumatic tourniquet for the upper limb. Varying thicknesses of two commercially-available types of orthopaedic padding (Cellona and Velband) were applied to the arms of 20 volunteers, with three pressure transducers placed directly beneath the padding. A tourniquet was positioned over the padding and inflated to 220 mmHg. Significant red...

متن کامل

Implementing AORN recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures.

Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1987