Optical coherence tomography in malignant glaucoma following filtration surgery.
نویسندگان
چکیده
AIM To assess the value of slit lamp adapted optical coherence tomography (OCT) for the management of malignant glaucoma following filtration surgery. METHODS Two patients (three eyes) developed malignant glaucoma following filtration surgery for primary open angle glaucoma (POAG). With slit lamp adapted OCT it was possible to image non-invasively the anterior chamber angle structures during the malignant glaucoma episode, and after pars plana vitrectomy (PPV) with anterior chamber reformation. RESULTS OCT revealed in both patients a markedly decreased anterior chamber angle with extreme shallowing of the anterior chamber depth during the acute malignant glaucoma phase. This critical closure of the anterior chamber angle resolved after PPV and deepening of the anterior chamber with viscoelastic. After PPV the quantitative values of the anterior chamber angle (ACA) and the anterior chamber opening distance (AOD) increased from 0 to an ACA of 35 degrees (SD 14 degrees ) and an AOD of 426 (SD 162) micro m. CONCLUSIONS Non-contact slit lamp adapted OCT was helpful to evaluate the anterior chamber structures in malignant glaucoma, and thus could improve management of this serious clinical disorder.
منابع مشابه
Macular thickness after glaucoma filtration surgery.
The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular dege...
متن کاملAnterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery
Time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) are cross-sectional, noncontact, high-resolution diagnostic modalities for posterior and anterior segment (AS) imaging. The AS-OCT provides tomographic imaging of the cornea, iris, lens, and anterior chamber (AC) angle in several ophthalmic diseases. In glaucoma, AS-OCT is utilized to evaluate the morphology of AS stru...
متن کاملOptical Coherence Tomography (OCT) of the Anterior Eye Segment
Description of Procedure or Service Optical coherence tomography (OCT) is a high resolution method of imaging the ocular structures. OCT for the anterior eye segment is being evaluated as a non-invasive diagnostic and screening tool for the detection of angle closure glaucoma, to assess corneal thickness and opacity, evaluate pre-surgical and postsurgical anterior chamber anatomy, calculate int...
متن کاملCorneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device
PURPOSE To report a case of corneal decompensation due to the Ex-PRESS(®) mini glaucoma shunt device (Ex-PRESS). PATIENT AND METHODS A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months. RESULTS We observed partial decompensation of the corneal endothelium adjacent to the filterin...
متن کاملAcute hypotony maculopathy following the initiation of a topical aqueous suppressant in a patient with a history of panuveitis without prior filtering surgery
Purpose To report a case of profound hypotony maculopathy as a complication of single-agent glaucoma therapy in a patient with a history of panuveitis without previous filtering surgery. Observations A 70-year old Hispanic male with a history of resolved bilateral panuveitis, chronic angle closure glaucoma, and pars plana vitrectomy was started on topical timolol 0.5% daily in the left eye fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 87 8 شماره
صفحات -
تاریخ انتشار 2003