OBJECTIVE To determine the complications of venous access devices (VADs) in cancer patients. SETTING Retrospective study in a tertiary referral center with specialist hematology and oncology services. SUBJECTS First one hundred consecutive patients who were implanted a VAD. All patients had an underlying cancer and the devices were inserted by the same surgeon. The duration of use of VADs and causes of their premature removal were noted. RESULTS One hundred VADs (55 port-a-caths and 45 Hickman's lines) were inserted in a total of 89 patients over a 7.5 year period. Majority of patients had acute myeloid leukemia (22) gastrointestinal malignancies (20) breast cancer (19) and genito-urinary cancers (15). The mean duration of use was 110 days; 157 days for the port-a-cath and 53 days for the Hickman's line. Nineteen devices (10 port-a-caths and 9 Hickman's lines) had to be removed prematurely. Two Hickman's lines got removed accidentally. The causes of premature removal included device failure (9), exist site infection (4), luminal infection (3) and tunnel infection (3). CONCLUSION The mean duration of use and the complication rates are comparable with studies reported in the literature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study

Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important.  ...

متن کامل

Effectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer

Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...

متن کامل

Totally implantable venous access devices in children with cystic fibrosis: incidence and type of complications.

BACKGROUND Totally implantable vascular access devices (TIVADs) are accepted as a safe and effective method of facilitating long term intravenous therapy. We report our experience of the use of these devices in children with cystic fibrosis with a particular focus on the incidence and type of complications. METHODS The medical records of patients with cystic fibrosis who underwent placement o...

متن کامل

Maim, death cases following the installation of vascular access devices filed with specialized forensic medicine commissions of Tehran, Iran, 2013-2018, (A descriptive study)

Background: Implantation of vascular access devices is of great importance in critically ill patients or those vulnerable to clinical worsening. The aim of this study was to identify the complications of implantation of vascular access leading to complaints from patients, in the forensic medicine commissions of Tehran. Methods: The present descriptive-cross sectional study was performed on all...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 51 12  شماره 

صفحات  -

تاریخ انتشار 2001