Predication of Life of Transformer insulation by developing Relationship between Degree of Polymerization and 2- Furfural

نویسندگان

  • Dipak Mehta
  • Hitesh Jariwala
چکیده

Degradation of cellulosic materials can be identified by measuring dissolved carbon oxide gas content in oil, Degree Polymerization (DP) of paper and 2-Furfurol content in oil. Each method has some advantages and limitations. In case of dissolved carbon oxide gas analysis and furan content determination, sampling is easy but interpretation of result is not very reliable. On the other hand DP measurement of paper is reliable and accurate but it is not practical top draw paper sample from transformer in service. Therefore, attempts are being made to establish a reliable and good correlation among above parameters to get a simple and accurate resu lt. This paper presents relation between DP and furan content. For given oil sample furan content first measured and using above relation DP value can be easily identified. Also this relationship is verified by with results of five no’s field failed transformers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transformer Paper Expected Life Estimation Using ANFIS Based on Oil Characteristics and Dissolved Gases (Case Study: Indonesian Transformers)

This article presents an algorithm for modelling an Adaptive Neuro Fuzzy Inference System (ANFIS) for power transformer paper conditions in order to estimate the transformer’s expected life. The dielectric characteristics, dissolved gasses, and furfural of 108 running transformers were collected, which were divided into 76 training datasets and another 32 testing datasets. The degree of polymer...

متن کامل

Aging Study of Transformer Oil-Impregnated Repulped and Standard Cellulose by Measuring of 2-furfural Content of the Oil

In order to evaluate the reliability of using repulped cellulose in transformers, the aging process was applied on standard and repulped cellulose in a laboratory accelerated model by increasing of temperature to 150 ° C and their behavior was monitored by measuring the amount of 2-furfural released in oil by HPLC (High Performance Liquid Chromatography) in the consecutive aging periods and...

متن کامل

Aging Study of Oil Impregnated Repulped and Standard Cellulose through Measuring Viscometric Degree of Polymerization

This paper describes the aging behavior of the oil impregnated repulped cellulose and compares it with the aging behavior of the oil impregnated standard cellulose. In order to evaluate the reliability of using repulped cellulose in transformers, the accelerated aging process was applied to both types of cellulose by increasing the temperature to 150 °C and their aging behavior was studied and ...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Study on Quantitative Correlations between the Ageing Condition of Transformer Cellulose Insulation and the Large Time Constant Obtained from the Extended Debye Model

Polarization-depolarization current (PDC) measurements are now being used as a diagnosis tool to predict the ageing condition of transformer oil-paper insulation. Unfortunately, it is somewhat difficult to obtain the ageing condition of transformer cellulose insulation using the PDC technique due to the variation in transformer insulation geometry. In this literature, to quantify the ageing con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012