Automated liquid-chromatographic analyzer used for toxicology screening in a general hospital: 12 months' experience.

نویسندگان

  • N Sadeg
  • G François
  • B Petit
  • H Dutertre-Catella
  • M Dumontet
چکیده

We evaluated the clinical utility of an automated HPLC system (Remedi, Bio-Rad) for identification of drugs and metabolites in biological fluids. Serum or urine or both from 354 consecutive cases of poisoning were analyzed by the system and by a set of fluorescence polarization immunoassay (FPIA, Abbott) and thin-layer chromatographic (TLC) procedures. Antidepressants and most phenothiazines were recognized by the new system. Comparison of Remedi results with final clinical diagnoses yielded diagnostic specificity and sensitivity of 80% and 90%, respectively. Remedi detected 26 additional compounds that were neither reactive in the immunoassay screening tests nor detected by TLC procedures. Because the Remedi expands the range of drugs covered by the immunoassays and provides a rapid, preliminary report in emergency situations, we conclude that this system can be a useful complementary technique in the clinical toxicology laboratory. Although urine toxicological screening seemed adequate for a good toxicological report, blood analysis allows extra toxicokinetic data such as blood concentrations and half-life estimations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of the First Metabolite-based LC-MS Urine Drug Screening Procedure

Screening for toxic compounds or drugs (TCD) in different body samples is one of the major tasks in clinical and forensic toxicology as well as in doping control. Several procedures using different separation and/or detection systems were used for screening purposes in the field of analytical toxicology [1]. While immunoassays allow a quick screening for a limited number of targets, chromatogra...

متن کامل

Simultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)

A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...

متن کامل

Simultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)

A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 1997