Use of image-free navigation in determination of acetabular cup orientation: analysis of factors affecting precision.
نویسندگان
چکیده
We have been using an image-free total hip arthroplasty (THA) navigation system (OrthoPilot; Aesculap, Tuttlingen, Germany) to ensure accurate and reproducible acetabular cup orientation. In this study, the accuracy of this system in the assessment of acetabular cup orientation was evaluated by comparing the intraoperative inclination and anteversion angles presented by the navigation system and the corresponding postoperative values obtained by computed tomography measurement. In the intraoperative accuracy analysis, we additionally examined the influence of factors such as body mass index and soft tissue thickness on assessment error. Intraoperative and postoperative results obtained from 115 consecutive navigated THAs were compared and analyzed. In both inclination and anteversion angles, good agreement was observed; a discrepancy of more than 5° was observed in 1 and 3 cases, respectively. In the analysis of factors potentially affecting the accuracy of the intraoperative assessment, no correlation between each parameter and the intraoperative and postoperative discrepancy was demonstrated.
منابع مشابه
Computed tomography assessment of image-free navigation-assisted cup placement in THA in an Asian population.
The authors hypothesized that an image-free navigation system would be more accurate than postoperative 3-dimensional (3-D) reconstructed computed tomography (CT) for acetabular cup inclination and anteversion during total hip arthroplasty (THA) in an Asian population. Eighty-one THAs were performed in 72 patients using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen,...
متن کاملValidation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-...
متن کاملImproving cup positioning using a mechanical navigation instrument.
BACKGROUND Although surgical navigation reduces the rate of malpositioned acetabular cups in total hip arthroplasty (THA), its use has not been widely adopted. As a result of our perceived need for simple and efficient methods of navigation, we developed a mechanical navigation device for acetabular cup orientation. QUESTIONS/PURPOSES We assessed accuracy of cup orientation (mean error of cup...
متن کاملComputer - Assisted Navigation for Acetabular Cup Placement : a Single Image Guiding System
Incorrect angular placement of the acetabular cup in total hip replacement induces femoral head dislocation, osteolysis, and liner wearing. Some computer-assisted navigation systems to aid acetabular cup placement have been developed in the past decade, but these are not used extensively due to their expense. In this study, a novel algorithm to determine the positions of data points in three-di...
متن کاملAn Image Guided Navigation System for Accurate Alignment in Total Hip Replacement Surgery
Dislocation following total hip replacement surgery (THR) remains a significant clinical problem. Malposition of the acetabular component increases the occurrence of impingement, reduces the " safe " range of motion and increases the risk of dislocation. Not fully understanding the interaction between pelvic orientation and final acetabular cup alignment may be one of the main contributing fact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 33 10 Suppl شماره
صفحات -
تاریخ انتشار 2010