Validation of a Flexible Optimal Control Approach for Rf- Pulse-design including Relaxation Effects and Sar

نویسندگان

  • Christoph Stefan Aigner
  • Christian Clason
  • Armin Rund
  • Rudolf Stollberger
چکیده

 Radio frequency (RF) pulses are essential in MRI to excite and alter magnetization. We present and validate a flexible approach based on optimal control of the full time-dependent Bloch equation, including relaxation effects. A globally convergent trust-region Newton method with exact derivatives via adjoint calculus allows the efficient computation of optimal pulses. The results are validated on a 3T scanner and demonstrate the ability to generate optimized pulses for arbitrary flip angles and arbitrary slice profiles. Keywords MRI, RF-pulse-design, slice selective excitation, optimal control theory

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local and global SAR constrained large tip angle 3 D kT - points parallel transmit pulse design at 7 T

In the last decade, there has been a push towards higher main field strengths in magnetic resonance imaging (MRI) to achieve better contrast and higher signal to noise ratio (SNR). A drawback to current imaging systems at high field is transmit magnetic field inhomogeneity, which degrades both SNR and contrast. This inhomogeneity can be mitigated through radio frequency (RF) pulse design with c...

متن کامل

Optimal control of coupled spin dynamics: design of NMR pulse sequences by gradient ascent algorithms.

In this paper, we introduce optimal control algorithm for the design of pulse sequences in NMR spectroscopy. This methodology is used for designing pulse sequences that maximize the coherence transfer between coupled spins in a given specified time, minimize the relaxation effects in a given coherence transfer step or minimize the time required to produce a given unitary propagator, as desired....

متن کامل

A Minimum SAR RF Pulse Design Approach for Parallel Tx with Local Hot Spot Suppression and Exact Fidelity Constraint

Introduction With increasing field-strength, the local specific absorption rate (SAR) becomes a limiting factor for MR imaging applications. However, using parallel Tx systems, it becomes possible to tailor the E-fields in the RF pulse design. Certain SAR optimal algorithms have been proposed, e.g. [1], that constrain a specific local region for SAR (e.g., the eyes). This is in general insuffic...

متن کامل

Broadband, Shallow Tip NMR Pulse Design Providing Uniform Tipping in Inhomogeneous RF Fields

Introduction Although high-field MRI on the human head offers a number of advantages including increased signal-to-noise ratio (SNR), and higher contrast for certain applications, there are also significant difficulties. Chief among these are the non-uniform tipping (variation of the flip angle in the sample) produced by conventional RF pulses due to the inhomogeneous RF (B1) field intrinsic in...

متن کامل

Designing Rf Pulses with Optimal Specific Absorption Rate (sar) Characteristics and Exploring Excitation Fidelity, Sar and Pulse Duration Tradeoffs

INTRODUCTION: Recent methods of designing RF pulses for multi-coil TX systems have focused on solving regularized systems of equations. These techniques linearize the equations relating the RF waveforms to the resulting excitation and then penalize RF candidates with high peak and root-mean-square (RMS) voltages (VP and VRMS, respectively) in an attempt to limit SAR [1,2]. This is sensible beca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014