100 Gbps IM/DD links using quad-polarization: Performance, complexity, and power dissipation.

نویسندگان

  • S Saldaña Cercós
  • M Piels
  • J Estarán
  • M Usuga
  • E Porto da Silva
  • A Manolova Fagertun
  • I Tafur Monroy
چکیده

A computational complexity, power consumption, and receiver sensitivity analysis for three different scenarios for short-range direct detection links is presented: 1) quad-polarization, 2) wavelength division multiplexing (WDM), and 3) parallel optics. Results show that the power consumption penalty associated to the quad-polarization digital signal processing (DSP) is negligibly small. However, the required analog to digital converters account for 47.6% of the total system power consumption. Transmission of 4×32 Gbps over 2 km standard single mode fiber is achieved with a receiver sensitivity of 4.4 dBm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

quad-polarization: Performance, complexity, and power dissipation

A computational complexity, power consumption, and receiver sensitivity analysis for three different scenarios for short-range direct detection links is presented: 1) quad-polarization, 2) wavelength division multiplexing (WDM), and 3) parallel optics. Results show that the power consumption penalty associated to the quad-polarization digital signal processing (DSP) is negligibly small. However...

متن کامل

A Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout

Optical data links are used in detector front-end electronics readout systems of experiments in the Tevatron and the LHC. Optical links in high energy particle physics experiments usually have special requirements such as radiation tolerance, ultra high reliability and low power dissipation. These requirements are often not met by commercial components which are designed for applications in non...

متن کامل

Conference title, upper and lower case, bolded, 18 point type, centered

We investigate a symmetrical 40 Gbps PON using 10-Gbps class optical components. We demonstrate transmission at 40 Gbps, with 23-dB power budget and 4.6∙10 BER after 10-km SSMF transmission using discrete multitone IM-DD. OCIS codes: (060.2330) Fiber optics communications; (060.4080) Modulation.

متن کامل

Performance Limitations of an Optical IM-DD Transmission System Due to Polarization Mode Dispersion

An analytical approach is presented to evaluate the impact of polarization mode dispersion on the average bit error rate (BER) performance of a intensity modulated direct detection (IM-DD) optical transmission system considering Maxwellian distribution for the differential group delay (DGD). The results show that the performance of an IM-DD system suffers power penalty of 0.27 dB, 0.45 dB and 2...

متن کامل

Efficient Heat Dissipation of Uncooled 400-Gbps (16×25-Gbps) Optical Transceiver Employing Multimode VCSEL and PD Arrays

An effective heat dissipation of uncooled 400-Gbps (16×25-Gbps) form-factor pluggable (CDFP) optical transceiver module employing chip-on-board multimode 25-Gbps vertical-surface-emitting-laser (VCSEL) and 25-Gbps photodiode (PD) arrays mounted on a brass metal core embedded within a printed circuit board (PCB) is proposed and demonstrated. This new scheme of the hollow PCB filling with thermal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 23 15  شماره 

صفحات  -

تاریخ انتشار 2015