Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing.

نویسندگان

  • Youn-Soo Park
  • Sung-Kwan Hwang
  • Won-Sik Choy
  • Yong-Sik Kim
  • Young-Wan Moon
  • Seung-Jae Lim
چکیده

BACKGROUND The mechanical properties of alumina ceramic, now in its third generation, have been markedly improved through the evolution of design features and manufacturing processes and the introduction of proof-testing. Nonetheless, because of the lack of ductility of alumina ceramic, there is concern regarding the risk of fracture during insertion or in vivo use. The purpose of the present study was to present a multicenter review of primary total hip arthroplasties performed with use of a polyethylene-ceramic composite liner combined with a ceramic femoral head, with particular attention to failure of the ceramic bearing. METHODS We evaluated 357 primary total hip arthroplasties that had been performed in 319 patients with use of a contemporary alumina-on-alumina bearing design incorporating a polyethylene-ceramic composite liner within a titanium-alloy shell coupled with a 28-mm-diameter ceramic femoral head. The procedures were performed at four participating centers from 1998 to 2001. Ceramic failure without trauma occurred in six hips (1.7%). All of these hips were revised, and the retrieved alumina implants were examined by means of visual inspection and scanning electron microscopy equipped with energy-dispersive x-ray spectrometry. RESULTS Two femoral heads fractured during the first postoperative year, and four alumina liners fractured after an average of 36.8 months in vivo. All four of the explanted alumina liners revealed evidence of rim contact with the metal neck of the femoral component. Composition analysis confirmed that surface-stain materials were titanium particles transferred from the femoral component. CONCLUSIONS Despite the theoretical improvement in the fracture toughness of a polyethylene-alumina composite liner, a relatively high rate of catastrophic ceramic bearing surface failure was still observed at the time of short-term follow-up. This finding prompted us to discontinue the use of this type of alumina bearing design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...

متن کامل

Fracture of the alumina-bearing couple delta ceramic liner.

The fracture rate of third-generation ceramic liners is greatly reduced compared with first- and second-generation liners because of improvements in the design and manufacturing process. Fractures of the alumina-bearing couple are rare for the same reason.This article describes a case of a fracture of an alumina-bearing couple delta ceramic liner without trauma history that was treated with cer...

متن کامل

Fracture of ceramic components as a serious failure after total hip replacement with ceramic-on-ceramic bearings

Introduction Ceramics have been introduced in total hip arthroplasty for several advantages including minimal friction, low wear, biocompatibility, no ageing problems and no problems related to the systemic increases in serum metal concentrations. In the first generation of ceramic components introduced in the 1970’s the risk of fracture was substantial, reaching up to 13.4 %. After introducing...

متن کامل

Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...

متن کامل

Use of an alumina ceramic-on-alumina ceramic bearing surface in THA in a 13 year old with JIA--a single case study.

Total hip arthroplasty (THA) has been shown to be highly effective in ameliorating pain and increasing function in adults with end stage arthritis of the hip. Early studies of cemented THA in children with advanced hip disease reported poor results, but, more recently, results of cementless THA show greatly improved outcomes. More recently, concerns related to THA in children have focused on we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2006