Multi-channel atomic magnetometer for magnetoencephalography: A configuration study

نویسندگان

  • Kiwoong Kim
  • Samo Begus
  • Hui Xia
  • Seung-Kyun Lee
  • Vojko Jazbinsek
  • Zvonko Trontelj
  • Michael V. Romalis
چکیده

Atomic magnetometers are emerging as an alternative to SQUID magnetometers for detection of biological magnetic fields. They have been used to measure both the magnetocardiography (MCG) and magnetoencephalography (MEG) signals. One of the virtues of the atomic magnetometers is their ability to operate as a multi-channel detector while using many common elements. Here we study two configurations of such a multi-channel atomic magnetometer optimized for MEG detection. We describe measurements of auditory evoked fields (AEF) from a human brain as well as localization of dipolar phantoms and auditory evoked fields. A clear N100m peak in AEF was observed with a signal-to-noise ratio of higher than 10 after averaging of 250 stimuli. Currently the intrinsic magnetic noise level is 4fTHz(-1/2) at 10Hz. We compare the performance of the two systems in regards to current source localization and discuss future development of atomic MEG systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chip - Scale Room - Temperature Atomic Magnetometers for Biomedical Measurements

We describe a portable four-channel array of chip-scale atomic magnetometers in a flexible flying-lead configuration. These microfabricated, uncooled sensors with volumes below 1 cm 3 demonstrate sensitivities around 100 fT/Hz 1/2 and bandwidths of several hundred hertz. Performance limits are discussed, as the design is easily scalable to different sensor sizes and large arrays. Initial measur...

متن کامل

A compact, high performance atomic magnetometer for biomedical applications.

We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) m...

متن کامل

Double Relaxation Oscillation SQUID Systems for Biomagnetic Multichannel Measurements

Multichannel superconducting quantum interference device (SQUID) systems based on double relaxation oscillation SQUIDs (DROS) were developed for measuring magnetocardiography (MCG) and magnetoencephalography (MEG) signals. Since DROS provides large fluxto-voltage transfer coefficients, about 10 times larger than the DC SQUIDs, direct readout of the SQUID output was possible using compact roomte...

متن کامل

Lokalizacija stimuliranega signala audio korteksa posnetega z magnetometrom na kalijeve pare

We present results of our study in localization of the auditory evoked magnetic field measured by a noncryogenic potassium vapour atomic magnetometer (PVAM) [5]. The magnetometer was operating in a spin-exchange relaxation-free (SERF) regime at low magnetic flux densities and high alkali-metal vapour density [1]. Audio stimulation of short 1 kHz pulse trains was applied by a pneumatic earphone....

متن کامل

A High-Sensitivity Tunable Two-Beam Fiber-Coupled High-Density Magnetometer with Laser Heating

Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz1/2 sensitivity at low frequency (50 Hz), whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2014