The use of a new breath-actuated inhaler by patients with severe airflow obstruction.

نویسندگان

  • R J Fergusson
  • J Lenney
  • G J McHardy
  • G K Crompton
چکیده

The ability of patients with severe airflow limitation (forced expiratory volume in one second less than 1.0 l or peak expiratory flow rate less than 200 l.min.1) to use a new breath-actuated inhaler (BAI) was assessed. One hundred and fifty six patients attending two respiratory units entered and completed the study. Subjects were instructed how to use the device and after attempting to trigger the BAI had flow-volume loops measured. One hundred and fifty one (97%) were able to actuate the inhaler on their first (146) or second (5) attempt. The five unsuccessful patients did not have the most severe airways obstruction. It is concluded that this new device, which is actuated at low inspiratory flow rates, can be used by patients with severe airflow limitation and represents an important advance in inhaler technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of a simple demand inhalation MDI aerosol delivery device.

Inhalation of medication is the preferred method for treating reversible airway obstruction; however, difficulties in the use of pressurized canisters frequently lead to suboptimal results. The Aerochamber (Monoghan Medical Corp) is a portable breath-actuated device that attaches to a metered-dose inhaler (MDI) and is designed to overcome many of the problems of aerosol delivery encountered by ...

متن کامل

Practical problems with aerosol therapy in COPD.

Inhaled aerosol drugs commonly used by patients with chronic obstructive pulmonary disease include short-acting and long-acting bronchodilators, as well as corticosteroids. These agents are available in a variety of inhaler devices, which include metered-dose inhalers (MDI), breath-actuated MDIs, nebulizers, and, currently, 5 different models of dry powder inhaler (DPI). There is evidence to su...

متن کامل

Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.

BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilat...

متن کامل

New inhalation devices.

ll is now accepted that inhaled bronchodilator therapy is, whenever possible, to be preferred to oral treatment in the routine management of reversible airflow obstruction [1). However, during the last two decades we have repeatedly been reminded that many patients have great difficulty in using the conventional pressurized metered dose inhaler (MDI) [2-6], today's most frequently prescribed in...

متن کامل

An assessment of a new breath actuated inhaler device in acutely wheezy children.

A randomised double blind, two period cross over study was designed to compare the ability of 51 hospitalised asthmatics with acute exacerbations to use each of two inhalers. The inhalers compared were a new breath actuated metered dose inhaler, the Autohaler inhalation device, and a dry powder device, the Rotahaler. Preassessment data included the measurement of peak inspiratory flow rate (PIF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 1991