Evaluation of agglutination strength by a flow-induced cell movement assay based surface plasmon resonance (SPR) technique.

نویسندگان

  • Krisda Sudprasert
  • Patjaree Peungthum
  • Apirom Vongsakulyanon
  • Ratthasart Amarit
  • Armote Somboonkaew
  • Boonsong Sutapun
  • Pimpun Kitpoka
  • Mongkol Kunakorn
  • Toemsak Srikhirin
چکیده

A flow-induced cell movement assay combined with a surface plasmon resonance (SPR) technique was developed to quantify the agglutination strength, derived from the standard tube-agglutination test. Red blood cells (RBCs), based on the ABO blood group system, were specifically captured by anti-A and/or anti-B antibodies immobilized on a sensor surface. The agglutination strength corresponds to the amount of antigen-antibody interactions or the strength of RBC adhesion. Under a shear flow, the adherent RBCs were forced to move out of the region of interest with different average cell velocities (vc) depending upon the adhesion strength and wall shear stress (WSS). That is, a higher adhesion strength (higher agglutination strength) or lower WSS represents a lower vc or vice versa. In this work, the agglutination strength was derived from the vc that was calculated from the time derivative of the relative SPR signal by using a simple model of cell movement response, whose validity was verified. The vc values of different samples were correlated with their agglutination strengths at a given WSS and antibody surface density. The vc decreased as the agglutination strength increased, which can be considered as a linear regression. The coefficient of variation of the calculated vc decreased to 0.1 as vc increased to 30 μm min(-1). The sensitivity of this assay can be controlled by optimizing the antibody surface density or the WSS. This assay has the capability to resolve the antigen density of A1 and B RBCs from that of A1B RBCs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ABO Blood-Typing Using an Antibody Array Technique Based on Surface Plasmon Resonance Imaging

In this study, readily available antibodies that are used in standard agglutination tests were evaluated for their use in ABO blood typing by a surface plasmon resonance imaging (SPR imaging) technique. Five groups of antibodies, including mixed clones of anti-A, anti-B, and anti-AB, and single clones of anti-A and anti-B, were used to construct the five-line detection arrays using a multichann...

متن کامل

Preliminary Results of Treating Cancerous Cells of Lung (QU-DB) by Hyperthermia using Diode Laser and Gold Coated Fe3O4/SiO2 Nano-Shells: An in-Vitro Assay

Introduction In this study, we describe the results of controlled synthesis and application of gold coated Fe3O4/SiO2 nano-shells combined with the optical property of gold for enhancement of selective photothermal interaction with cancerous cells based on the surface plasmon resonance (SPR) Phenomena. Materials and Methods Magnetite Nano-Particles (MNPs) were prepared by means of co-precipitat...

متن کامل

Optimization of Sensitivity and Stability of Gold/Silver bi-Layer Thin Films Used in Surface Plasmon Resonance Chips

The aim of this study is experimental assay of sensitivity and stability of a bimetallic silver/gold SPR sensor chip. This chip utilizes the sensitivity of the silver and the stability of the gold. Moreover, the Silver layer (instead of usual Cr or Ti layer) was used as an adhesive intermediate layer between the Gold layer and the glass substrate. The optimization of the Gold/Silver thickness u...

متن کامل

Antibody Conjugated Gold Nanoparticles for Detection of Small Amounts of Antigen Based on Surface Plasmon Resonance (SPR) Spectra

In this paper, a fast and sensitive localized surface plasmon resonance (LSPR) based biosensor was developed and the optimization of gold – antibody conjugates through investigation of different parameters were performed. Gold nanoparticles (AuNPs) with a size of ~20 nm were synthesized via chemical reduction of HAuCl4 with trisodium citrate as reducing and stabilizing agent. The impacts of pH ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 3  شماره 

صفحات  -

تاریخ انتشار 2015