An analysis of post-pacing R-R intervals during atrial fibrillation.

نویسندگان

  • F Morady
  • L A DiCarlo
  • R B Krol
  • M De Buitleir
  • J M Baerman
چکیده

Bursts of ventricular pacing at cycle lengths of 350-260 ms were introduced during atrial fibrillation in nine patients, and the post-pacing R-R intervals were compared to the R-R intervals of spontaneous QRS complexes. In eight of nine patients, the mean post-pacing R-R interval was 126-199 ms longer than the mean spontaneous R-R interval (p less than 0.005). Spontaneous runs of aberrantly conducted supraventricular complexes were recorded during atrial fibrillation in one patient. The mean R-R interval following the runs of aberrantly conducted supraventricular complexes was significantly longer than the mean R-R interval of spontaneous narrow QRS complexes (p less than 0.001), but not significantly different than the mean post-pacing R-R interval. The findings of this study suggest that the R-R interval that follows a wide-complex tachycardia during atrial fibrillation is unlikely to be of value in differentiating ventricular tachycardia from aberrantly conducted supraventricular complexes. Analysis of R-R intervals that follow bursts of ventricular pacing suggests that there is likely to be considerable overlap between the R-R intervals that follow runs of ventricular tachycardia and the spontaneous R-R intervals during atrial fibrillation. Furthermore, even when the post-tachycardia R-R interval clearly exceeds the longest spontaneous R-R interval during atrial fibrillation, this is still of little diagnostic value, because a long pause may occur after either a run of ventricular tachycardia or a run of aberrantly conducted QRS complexes of supraventricular origin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

New manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart

Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...

متن کامل

Effective use of a novel rate-smoothing algorithm in atrial fibrillation by ventricular pacing.

BACKGROUND It is still unknown whether a fast heart rate or an irregular ventricular response in atrial fibrillation causes tachycardiomyopathy. Reduction in the variability of RR intervals without an increase in heart rate might be an alternative treatment when antiarrhythmic drugs fail to control the irregularity accompanying atrial fibrillation. SUBJECTS AND METHODS Eight patients underwen...

متن کامل

CRP: does it stand for C oronary R estenosis P rediction?

fibrillation recedes very rapidly after the first few minutes following cardioversion as a result of the rapid early phase of reverse remodelling of atrial myocardial electrophysiology, to pace the atria rapidly during this period, such as the 300 ms intervals as in the study in this issue, may actually attenuate this reverse remodelling and perpetuate the profibrillatory state. This may explai...

متن کامل

Effect of atrial antitachycardia pacing treatments in patients with an atrial defibrillator: randomised study comparing subthreshold and nominal pacing outputs.

OBJECTIVE To assess the true efficacy of antitachycardia pacing on spontaneous persistent atrial fibrillation in patients with an implanted atrial defibrillator, by comparing the effects of nominal pacing treatment with subthreshold pacing treatment. DESIGN The effects of antitachycardia pacing and burst 50 Hz atrial pacing on spontaneous atrial arrhythmias were evaluated six months after imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 1986