Laser Ablation ICP-MS of Actinide Oxides as Simulated Used Nuclear Fuels
نویسندگان
چکیده
منابع مشابه
Analysis of trace metals in comparison of laser-induced breakdown spectroscopy with LA-ICP-MS
Laser-induced breakdown spectroscopy (LIBS) and LA-ICP-MS (laser ablation inductively coupled plasma mass-spectrometry) were used for the detection of trace metals in a solid matrix consisting of KBr and two oxides. The results of both methods were compared to investigate the strengths and weaknesses of both methods. Most difficulties for quantification of LIBS data are related to matrix effect...
متن کاملThe influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS.
Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-inde...
متن کاملLaser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Major and severe accidents have occurred three times in nuclear power plants (NPPs), at Three Mile Island (USA, 1979), Chernobyl (former USSR, 1986) and Fukushima (Japan, 2011). Research on the causes, dynamics, and consequences of these mishaps has been performed in a few laboratories worldwide in the last three decades. Common goals of such research activities are: the prevention of these kin...
متن کاملA comparison of techniques for measuring the trace element content of human teeth: laser ablation ICP-MS versus solution ICP-MS of micromilled enamel
Through analysis of their chemical composition, human teeth may serve as retrospective bioindicators of preand postnatal nutrition and exposures to environmental pollutants. The research presented here explores the agreement of laser ablation ICP-MS and solution ICP-MS analyses aimed at capturing temporal changes in the trace element composition of enamel. Good agreement was found for LA-ICP-MS...
متن کاملLaser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS): comparison of different internal standardization methods using laser-induced plasma (LIP) emission and LA-ICP-MS signals.
The source of signal variations that governs the analytical performance of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was investigated in this study. In order to specify the source of signal variations of LA-ICP-MS, laser-induced plasma (LIP) Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards for the determination of trace elements ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017