A more accurate method of measurement of angulation after fractures of the tibia.

نویسنده

  • S A Milner
چکیده

Accurate measurement of the alignment of the tibia is important both clinically and in research. The conventional method of measuring the angle of malunion after a fracture of the shaft of the tibia is potentially inaccurate because the mechanical axis of the normal bone may not pass down the centre of the medullary canal. An alternative method is described in which a radiograph of the opposite tibia is used as a template. A sample of 56 sets of standard radiographs of healed fractures of the shaft of the tibia was evaluated. The 95% limits of agreement between this and the conventional method were wide, being -6.2 degrees to +5.5 degrees for coronal angulation and -6.7 degrees to +8.1 degrees for sagittal angulation. These results suggest that the conventional method is inaccurate. The new method has good inter- and intraobserver reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

Outcomes of the isolated closed tibial shaft fractures treated nonsurgically

  Abstract   Background: Fractures of the tibia are important for their commonness and controversy in their management. Both conservative and surgical techniques have been introduced in an effort to speed time to :::union::: while minimizing the occurrence of complications. Standard treatment for low-energy tibial shaft fractures includes closed reduction and cast immobilization. The purpose of...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

Assessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating

  Abstract   Background: The tibial diaphyseal fractures are the most common type of long   bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia   fractures have the second incidence of all tibia fractures after the middle tibia fractures.   The purpose of the study was to asses...

متن کامل

Residual angulation of distal tibial diaphyseal fractures in children younger than ten years

BACKGROUND The purpose of this study was to evaluate the factors that influence residual angulation after treating pediatric distal tibial diaphyseal fractures. METHODS We retrospectively reviewed the records of 75 children under the age of ten who were treated at two referral centers for distal tibial diaphyseal fractures. The mean patient age was 6.8 ± 2.3 years, and the mean follow-up dura...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 79 6  شماره 

صفحات  -

تاریخ انتشار 1997