Optimization of Spectrally Coded Mask for Multi-modal Plenoptic Camera

نویسندگان

  • Kathrin Berkner
  • Sapna Shroff
چکیده

We introduce a framework to optimize the spatial layout of a spectral filter mask inserted into the aperture of a plenoptic camera. The optimization merit function evaluates end-to-end system performance, including spectral crosstalk at the sensor caused by lens aberrations and diffraction effects. We use the example of a Bayer pattern to illustrate the effects of optimized filter partitions on the system performance. © 2011 Optical Society of America OCIS codes: 110.1758, 110.4234, 070.0070

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design framework for a spectral mask for a plenoptic camera

Plenoptic cameras are designed to capture different combinations of light rays from a scene, sampling its lightfield. Such camera designs capturing directional ray information enable applications such as digital refocusing, rotation, or depth estimation. Only few address capturing spectral information of the scene. It has been demonstrated that by modifying a plenoptic camera with a filter arra...

متن کامل

System Model and Performance Evaluation of Spectrally Coded Plenoptic Camera

We introduce an end-to-end imaging system model for a spectrally coded plenoptic camera. The model includes a system-dependent spectral demultiplexing algorithm and is used to evaluate spectral quality and classification performance of a spectrally coded plenoptic camera. © 2012 Optical Society of America OCIS codes: 110.1758, 110.4234, 100.3010.

متن کامل

Evaluation of multispectral plenoptic camera

Plenoptic cameras enable capture of a 4D lightfield, allowing digital refocusing and depth estimation from data captured with a compact portable camera. Whereas most of the work on plenoptic camera design has been based a simplistic geometric-optics-based characterization of the optical path only, little work has been done of optimizing end-to-end system performance for a specific application. ...

متن کامل

Multi-view Image Restoration from Plenoptic Raw Images

We present a reconstruction algorithm that can restore the captured 4D light field from a portable plenoptic camera without the need for calibration images. An efficient and robust estimator is proposed to accurately detect the centers of microlens images. Based on that estimator, parameters that model the centers of microlens array images are obtained by solving a global optimization problem. ...

متن کامل

Unconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibration

The plenoptic camera can capture both angular and spatial information of the rays, enabling 3D reconstruction by single exposure. The geometry of the recovered scene structure is affected by the calibration of the plenoptic camera significantly. In this paper, we propose a novel unconstrained two-parallel-plane (TPP) model with 7 parameters to describe a 4D light field. By reconstructing scene ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011