Evaluation of vestibulocochlear nerves in cases with acoustic schwannoma by direct sagittal oblique 3D-FIESTA MR imaging
نویسندگان
چکیده
Oblique sagittal MRI with 3D-FIESTA (3-D fast imaging employing steady-state acquisition) sequences can be obtained through the internal auditory canal (IAC) without relying on multi-planar reconstructions. The high spatial resolution direct sagittal oblique imaging technique is useful for the identification of the four intracanalicular nerves. This work included one case of IAC tumor and two cases of cerebellopontine angle (CPA) tumors. MR imaging using a 3D-FIESTA sequence was performed in the oblique sagittal plane perpendicular to the course of the IAC. The direct sagittal oblique imaging technique allowed clear delineation of the individual nerves of the IAC. In a case of acoustic schwannoma, which was surgically proven to originate from the inferior vestibular nerve (IVN), the results of vestibular assessment indicated an IVN pathology. Acquired cochlear nerve hypoplasia with moderate hearing loss was found in a case of CPA tumor. Correspondence to: Hidenobu Taiji, MD, Department of Otorhinolaryngology, Saiseikai Central Hospital, 1-4-17, Mita, Minato-ku, Tokyo 108-0073, Japan, Tel: +81 3 3451 8211; Fax: +81 3 3451 6102; E-mail: [email protected]
منابع مشابه
Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography.
PURPOSE The aim of this study was to compare 3D fast imaging with steady state acquisition (3D FIESTA) to fast spin echo T2-weighted (FSE T2W) MRI sequences in the imaging of cisternal parts of cranial nerves V-XII. MATERIALS AND METHODS We retrospectively evaluated the temporal MRI sequences of 50 patients (F:M ratio, 27:23; mean age, 44.5 +/- 15.9 years) who were admitted to our hospital wi...
متن کاملGadolinium Enhanced 3D Proton Density Driven Equilibrium MR Imaging in the Evaluation of Cisternal Tumor and Associated Structures: Comparison with Balanced Fast-Field-Echo Sequence
OBJECTIVES Although Gadolinium enhanced bFFE is commonly used to evaluate cisternal tumors, banding artifact may interrupt interpretation and adjacent nerve and vessels differentiation is known to be difficult. We analyzed the qualities of Gd enhanced 3D PDDE in the evaluation of cisternal tumors, comparing with bFFE. MATERIAL AND METHODS Forty five cisternal tumors (33 schwannoma and 12 meni...
متن کامل3D MR Neurography of the Lumbosacral Plexus: Obtaining Optimal Images for Selective Longitudinal Nerve Depiction.
BACKGROUND AND PURPOSE The number of centers currently performing 3D fat-suppressed isotropic imaging is limited. If the angular orientations of the major lumbosacral plexus nerves on 3D isotropic MR neurography could be determined, similar planes could be prescribed during acquisition of 2D or 3D nonisotropic techniques for optimal depiction of various nerves. Our aim was to determine oblique ...
متن کاملVascular loops at the cerebellopontine angle: is there a correlation with tinnitus?
BACKGROUND AND PURPOSE Tinnitus is a common disorder, and the etiology remains mostly unclear. The purpose of this study was to investigate the causative effect of the vascular loop and compression of the vestibulocochlear nerve at the cerebellopontine angle in patients with unexplained tinnitus. MATERIALS AND METHODS This study was approved by our institutional review board. Written informed...
متن کاملAnatomy of the facial and vestibulocochlear nerves in the internal auditory canal.
PURPOSE To define the anatomy of the facial and vestibulocochlear nerves in the internal auditory canal on parasagittal CT scans of cadaveric specimens and to compare this anatomy with findings on in vivo T2-weighted two-dimensional fast spin-echo and three-dimensional turbo spin-echo MR images. METHODS Thirty-eight formalin-fixed cadaveric temporal bones were examined with 1-mm-thick contigu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017