Evaluation and utilization of a kinetic enzyme direct measuring photometer.

نویسنده

  • P L Wolf
چکیده

We have recently utilized a prototype model of the Beckman Enzyme Activity Analyzer System-TR in our laboratory measuring various serum enzyme activities which include: alkaline phosphatase (ALP), E.C.3.1.3.1; creatine kinase (CK), E.C.2.7.3.2; hydroxybutyrate dehydrogenase (HBD), E.C.1.1.1.30; lactate dehydrogenase (LD), E.C.1.1.1.27; aspartate transaminase (AST), E.C.2.6.1.1; and alanine transaminase (ALT), E.C.2.6.1.2. Precision was found to be good. Sample activities could be measured as high as 1000 IU/1. The carryover studies fell within 2 SD of the means of the enzyme control studies. Coefficients of variation for ALP and CK were in the ranges of 0-40-2-14% and 0-52-4-30%, respectively. Correlation studies were done with GemSAEC and Gilford 300 N Spectrophotometer and the results were accurate, precise, and reproducible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, construction and calibration of single channel sun-photometer for study of aerosols

Aerosols are tiny liquid or solid particles suspended in the air have a strong influence on air quality, human health and climate change. Sun-photometer is a tool for measuring the optical and physical characteristics of aerosols by using sunlight at various wavelengths from the Earth surface. In this paper, the design, construction, and calibration of a single channel sun-photometer is present...

متن کامل

Growth Kinetic Survey in Direct Biological Sweetening of Natural Gas in Batch Bioreactor: Temperature Studies

The present study is focused on biodesulfurization of natural gas in a batch culture using active microorganisms. The microorganisms used for the removal of hydrogen sulfide were obtained from a hot spring. The experiments were conducted with mixed gas at operating temperatures of 25 to 45°C with a time interval of 5h. Two kinetic models included Logistic and Monod models in a batch culture wer...

متن کامل

Kinetic study of peroxidase enzyme in the presence of purine alkaloids

Peroxidase catalyzes different oxidation of substrates using hydrogen peroxide, a reactive oxygen specie (ROS). ROS, at low concentrations, act as messenger to regulate intracellular signaling, whereas, at high concentrations, they can overcome the immune system by creating oxidative stress. Some common beverages such as coffee, tea and soft drinks contain high levels of xanthine alkaloids incl...

متن کامل

Evaluation of calibration methods of a photometer measuring maritime light-emitting diode buoy lanterns

Erkki Ikonen Helsinki University of Technology Metrology Research Institute P.O. Box 3000 FIN-02015 HUT Finland Abstract. A photometer used for on-line product testing of light-emitting diode (LED) buoy lanterns is calibrated for illuminance responsivity using two different methods. The first method is based on absolute calibration of the photometer with the CIE standard illuminant A light sour...

متن کامل

Evaluation of Cell Growth and Substrate Consumption Kinetic of Five Different Lactobacilli in a Submerged Batch Whey Culture for Lactic Acid Production

Cell growth and lactose consumption profile of five Lactobacillus Strains: bulgaricus, casei, lactis, delbrueckii and fermentum has been investigated. Experiments of cell growth and substrate utilization were conducted in batch submerged culture of whey with added lactose and some other growth factors. Fitness assessment of experimental data on the cell growth and lactose consumption by Monod k...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 1975