Immuno-PCR: very sensitive antigen detection by means of specific antibody-DNA conjugates.

نویسندگان

  • T Sano
  • C L Smith
  • C R Cantor
چکیده

An antigen detection system, termed immuno-polymerase chain reaction (immuno-PCR), was developed in which a specific DNA molecule is used as the marker. A streptavidin-protein A chimera that possesses tight and specific binding affinity both for biotin and immunoglobulin G was used to attach a biotinylated DNA specifically to antigen-monoclonal antibody complexes that had been immobilized on microtiter plate wells. Then, a segment of the attached DNA was amplified by PCR. Analysis of the PCR products by agarose gel electrophoresis after staining with ethidium bromide allowed as few as 580 antigen molecules (9.6 x 10(-22) moles) to be readily and reproducibly detected. Direct comparison with enzyme-linked immunosorbent assay with the use of a chimera-alkaline phosphatase conjugate demonstrates that enhancement (approximately x 10(5)) in detection sensitivity was obtained with the use of immuno-PCR. Given the enormous amplification capability and specificity of PCR, this immuno-PCR technology has a sensitivity greater than any existing antigen detection system and, in principle, could be applied to the detection of single antigen molecules.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A covalent and cleavable antibody-DNA conjugation strategy for sensitive protein detection via immuno-PCR.

Immuno-PCR combines specific antibody-based protein detection with the sensitivity of PCR-based quantification through the use of antibody-DNA conjugates. The production of such conjugates depends on the availability of quick and efficient conjugation strategies for the two biomolecules. Here, we present an approach to produce cleavable antibody-DNA conjugates, employing the fast kinetics of th...

متن کامل

Development and evaluation of three real-time immuno-PCR assemblages for quantification of PSA.

Real-time PCR is a very sensitive technique to measure DNA concentrations. In real-time immuno-PCR, it is used as the detection system for quantification of proteins. Many ways to perform and assemble real-time immuno-PCR are possible. We have tested three different approaches for the detection of prostate specific antigen (PSA) and compared them with each other and with ELISA. We also demonstr...

متن کامل

Real-time femtomolar detection of cancer biomarkers from photoconjugated antibody-phage constructs.

Here we describe novel covalent conjugates of antibody-phage for the detection of multiple cancer biomarkers using real time immuno-polymerase chain reaction (immuno-PCR). While the conventional process of immuno-PCR utilizes DNA-conjugated antibodies, chemical modification of antibodies not only reduces antibody affinity but also creates a heterogeneous population of products. However, phage n...

متن کامل

Combination of DNA-directed immobilization and immuno-PCR: very sensitive antigen detection by means of self-assembled DNA-protein conjugates.

An assay for very sensitive antigen detection is described which takes advantage of the self- assembly capabilities of semi-synthetic conjugates of DNA and proteins. The general scheme of this assay is similar to a two-sided (sandwich) enzyme-linked immunoassay (ELISA); however, covalent single-stranded DNA-streptavidin (STV) conjugates, capable of hybridizing to complementary surface-bound DNA...

متن کامل

Site-specific DNA-antibody conjugates for specific and sensitive immuno-PCR.

Antibody conjugates are widely used as diagnostics and imaging reagents. However, many such conjugates suffer losses in sensitivity and specificity due to nonspecific labeling techniques. We have developed methodology to site-specifically conjugate oligonucleotides to antibodies containing a genetically encoded unnatural amino acid with orthogonal chemical reactivity. These oligobody molecules ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Science

دوره 258 5079  شماره 

صفحات  -

تاریخ انتشار 1992