Harms of unintentional leaks during volume targeted pressure support ventilation.

نویسندگان

  • Sonia Khirani
  • Bruno Louis
  • Karl Leroux
  • Vincent Delord
  • Brigitte Fauroux
  • Frédéric Lofaso
چکیده

BACKGROUND Volume targeted pressure support ventilation (VT-PSV) is a hybrid mode increasingly used to maintain a minimal tidal volume (VT) by automatically adjusting the level of inspiratory pressure. The objective of the study was to determine the ability of home ventilators to maintain the preset minimal VT during unintentional leaks in a VT-PSV mode. METHODS Seven ventilators were tested on a lung bench with different circuit configurations and with different levels of unintentional leaks. Unintentional leaks were generated using calibrated holes. RESULTS All the studied ventilators with a single-limb circuit with intentional leak (n = 5) were able to maintain the minimal preset VT during unintentional leaks. One ventilator overcompensated VT during unintentional leaks of high intensity. In contrast, all studied ventilators with a single circuit with an expiratory valve (n = 2) or a double-circuit (n = 3) but one failed to maintain the minimal VT during unintentional leaks. Unintentional leaks generated a decrease in inspiratory pressure, which was responsible for the fall in VT. CONCLUSIONS Most of the studied ventilators with a single-limb circuit with intentional leak correctly estimate the expiratory VT and therefore successfully maintain the preset minimal VT during unintentional leaks, in contrast to most of the studied ventilators with a double-circuit, which paradoxically are not able to directly measure expiratory VT. Importantly, the VT-PSV mode, when used with most ventilators with expiratory valve or double-circuit, can paradoxically exacerbate the VT drop during unintentional leaks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of dynamic leaks in volume-targeted pressure support noninvasive ventilation: a bench study.

INTRODUCTION The effect of leaks on volume-targeted pressure support noninvasive ventilation mode has only been tested with continuous simulated leaks. The objective of the study was to assess the influence of random leaks occurring either during inspiration or expiration. METHODS Analysis of the volume-targeted pressure support mode in 6 commercial ventilators with single-limb circuits and i...

متن کامل

Battery life of portable home ventilators: effects of ventilator settings.

BACKGROUND The battery life (BL) of portable home ventilator batteries is reported by manufacturers. The aim of this study was to evaluate the effects of ventilator mode, breathing frequency, PEEP, and leaks on the BL of 5 commercially available portable ventilators. METHODS The effects of the ventilator mode (volume controlled-continuous mandatory ventilation [VC-CMV] vs pressure support ven...

متن کامل

Leak compensation in positive pressure ventilators: a lung model study.

Leak compensating abilities of six different positive pressure ventilators commonly used to deliver noninvasive positive pressure ventilation, including the bilevel positive airway pressure (BiPAP) S/T-D and Quantum (Respironics Inc, Murrysville, PA, USA), 335 and O'NYX (Mallinckrodt Inc, St Louis, MO, USA), PLV 102 (Respironics), and Siemens Servo 900C (Siemens Inc, Danvers, MA, USA). Using a ...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Case Reports A Case of Pneumomediastinum in a Patient With Acute Respiratory Distress Syndrome on Pressure Support Ventilation

During mechanical ventilation for acute respiratory distress syndrome, tidal volume (VT) must be reduced. Once switched to pressure-support ventilation, there is a risk that uncontrolled large VT may be delivered. A 63-year-old man with community-acquired pneumonia required tracheal intubation and mechanical ventilation, with a VT of 6 mL/kg predicted body weight, PEEP of 10 cm H2O, a respirato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory medicine

دوره 107 7  شماره 

صفحات  -

تاریخ انتشار 2013