Liquid-metal-jet anode electron-impact x-ray source

نویسندگان

  • O. Hemberg
  • M. Otendal
  • H. M. Hertz
چکیده

We demonstrate an anode concept, based on a liquid-metal jet, for improved brightness in compact electron-impact x-ray sources. The source is demonstrated in a proof-of-principle experiment where a 50 keV, ;100 W electron beam is focused on a 75 mm liquid-solder jet. The generated x-ray flux and brightness is quantitatively measured in the 7–50 keV spectral region and found to agree with theory. Compared to rotating-anode sources, whose brightness is limited by intrinsic thermal properties, the liquid-jet anode could potentially be scaled to achieve a brightness .1003 higher than current state-of-the-art sources. Applications such as mammography, angiography, and diffraction would benefit from such a compact high-brightness source. © 2003 American Institute of Physics. @DOI: 10.1063/1.1602157#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 9 keV electron-impact liquid-gallium-jet x-ray source.

We demonstrate a high-brightness compact 9 keV electron-impact microfocus x-ray source based on a liquid-gallium-jet anode. A approximately 30 W, 50 kV electron gun is focused onto the approximately 20 ms, 30 mum diameter liquid-gallium-jet anode to produce an approximately 10 microm full width at half maximum x-ray spot. The peak spectral brightness is >2 x 10(10) photons(s mm(2) mrad(2)x0.1% ...

متن کامل

A 24 keV liquid-metal-jet x-ray source for biomedical applications.

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 μm full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K(α) line is 3 × 10(9) photons∕(s × mm(2) × mrad(2) × 0.1% BW) at...

متن کامل

Microscopic high-speed liquid-metal jets in vacuum

The operation of microscopic high-speed liquid-metal jets in vacuum has been investigated. We show that such jets may be produced with good stability and collimation at higher speeds than previously demonstrated, provided that the nozzle design is appropriate and that cavitation-induced instabilities are avoided. The experiments with a medium-speed tin jet (u 60 m/ s, Re=1.8·10, Z=2.9·10 ) show...

متن کامل

Phase-contrast x-ray imaging with a liquid-metal-jet-anode microfocus source

Phase-contrast methods increase contrast, detail, and selectivity in x-ray imaging. Present compact x-ray sources do not provide the necessary spatial coherence with sufficient power to allow the laboratory-scale high-resolution phase-contrast imaging with adequate exposure times. In this letter, the authors demonstrate phase-contrast imaging with few-micron detail employing a compact 6.5 m spo...

متن کامل

First application of liquid-metal-jet sources for small-animal imaging: high-resolution CT and phase-contrast tumor demarcation.

PURPOSE Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003