A 7 µm mini-beam improves diffraction data from small or imperfect crystals of macromolecules

نویسندگان

  • Ruslan Sanishvili
  • Venugopalan Nagarajan
  • Derek Yoder
  • Michael Becker
  • Shenglan Xu
  • Stephen Corcoran
  • David L. Akey
  • Janet L. Smith
  • Robert F. Fischetti
چکیده

A simple apparatus for achieving beam sizes in the range 5-10 μm on a synchrotron beamline was implemented in combination with a small 125 x 25 μm focus. The resulting beam had sufficient flux for crystallographic data collection from samples smaller than 10 x 10 x 10 μm. Sample data were collected representing three different scenarios: (i) a complete 2.0 data set from a single strongly diffracting microcrystal, (ii) a complete and redundant 1.94 A data set obtained by merging data from six microcrystals and (iii) a complete 2.24 A data set from a needle-shaped crystal with less than 12 x 10 μm cross-section and average diffracting power. The resulting data were of high quality, leading to well refined structures with good electron-density maps. The signal-to-noise ratios for data collected from small crystals with the mini-beam were significantly higher than for equivalent data collected from the same crystal with a 125 x 25 μm beam. Relative to this large beam, use of the mini-beam also resulted in lower refined crystal mosaicities. The mini-beam proved to be advantageous for inhomogeneous large crystals, where better ordered regions could be selected by the smaller beam.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated sample-scanning methods for radiation damage mitigation and diffraction-based centering of macromolecular crystals.

Automated scanning capabilities have been added to the data acquisition software, JBluIce-EPICS, at the National Institute of General Medical Sciences and the National Cancer Institute Collaborative Access Team (GM/CA CAT) at the Advanced Photon Source. A `raster' feature enables sample centering via diffraction scanning over two-dimensional grids of simple rectangular or complex polygonal shap...

متن کامل

Serial crystallography on in vivo grown microcrystals using synchrotron radiation

Crystal structure determinations of biological macromolecules are limited by the availability of sufficiently sized crystals and by the fact that crystal quality deteriorates during data collection owing to radiation damage. Exploiting a micrometre-sized X-ray beam, high-precision diffractometry and shutterless data acquisition with a pixel-array detector, a strategy for collecting data from ma...

متن کامل

Fully automatic characterization and data collection from crystals of biological macromolecules

Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data...

متن کامل

Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron

BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused configuration, where both mirrors can focus the beam at the sample position to 52 µm × 5.5 µm FWHM ...

متن کامل

Solvent minimization induces preferential orientation and crystal clustering in serial micro-crystallography on micro-meshes, in situ plates and on a movable crystal conveyor belt

X-ray diffraction data were obtained at the National Synchrotron Light Source from insulin and lysozyme crystals that were densely deposited on three types of surfaces suitable for serial micro-crystallography: MiTeGen MicroMeshes™, Greiner Bio-One Ltd in situ micro-plates, and a moving kapton crystal conveyor belt that is used to deliver crystals directly into the X-ray beam. 6° wedges of data...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta Crystallographica Section D: Biological Crystallography

دوره 64  شماره 

صفحات  -

تاریخ انتشار 2008