The accuracy of three impression transfer techniques for implant supported prostheses.

نویسندگان

  • H D Dullabh
  • L M Sykes
چکیده

Cast framework for osseointegrated implant retained prostheses need to be passively fitting so as not to place undue forces and stress concentrations around the fixtures. Impression materials and techniques play a key role in the accuracy and fit of the metal framework. In this study, three impression procedures were investigated to establish which was the most accurate, reliable and predictable. This included using smooth sided tapered transfer copings and unsplinted and splinted square undercut transfer copings. A metal plated master model was fabricated and used as the standard against which models poured using the different impression techniques were compared. Readings were taken with a Reflex Microscope and used to calculate the mean, standard deviation and deviation index for each test model. The results of this study suggest that direct coping transfer techniques provide comparable or better results than indirect coping transfers in master cast fabrication. There was no significant difference in impression transfer accuracy between splinted and non-splinted square impression coping transfer techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

Statement of the Problem Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the ...

متن کامل

Effect of Three Types of Temporary Luting Cements and Abutment Surface Sandblasting on Retentive Strength of Implant-Supported Fixed Prostheses

Background and Aim: Achieving appropriate retention and easy retrieva bility at the same time is challenging in implant-supported fixed par tial dentures (FPDs). Researchers have always been in search of a temporary cement to improve the retentive strength. The aim of this in vitro study was to evaluate the effect of three different temporary ce ments and sandblasting of the abutment surface on...

متن کامل

Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.

PURPOSE The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques--specifically, splinted versus nonsplinted--on the accuracy of fit of fixed implant prostheses in edentulous patients. MATERIALS AND MET...

متن کامل

Case Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report

Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...

متن کامل

Reducing Distortion of Implant- or Abutment-Level Impressions for Implant-Supported Prosthetic Rehabilitation: A Technique Report.

Passive fit between prosthesis and implants or abutments is a significant factor in preventing mechanical and biologic failures of implant-supported prostheses. Therefore, impression techniques must transfer the 3D implant position as accurately as possible for a correct superstructure fabrication. A novel impression protocol that uses an individualized open tray design is proposed. It allows t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • SADJ : journal of the South African Dental Association = tydskrif van die Suid-Afrikaanse Tandheelkundige Vereniging

دوره 63 8  شماره 

صفحات  -

تاریخ انتشار 2008