Comparison of the usage of intravenous iloprost and nitroglycerin for pulmonary hypertension during valvular heart surgery.

نویسندگان

  • Ayse Baysal
  • Serpil Bilsel
  • Ozlem Gumustekin Bulbul
  • Ilyas Kayacioglu
  • Mustafa Idiz
  • Ibrahim Yekeler
چکیده

BACKGROUND Pulmonary hypertension secondary to valvular heart disease is a cause of acute right heart failure during valve replacement operations. This study compares the hemodynamic effects of intravenous use of iloprost and nitroglycerin in patients with pulmonary hypertension undergoing valvular replacement surgery. We sought to determine the acceptable doses of these medications for use in surgery to decrease mean pulmonary artery pressure to <30 mmHg without causing systemic side effects. The plasma nitric oxide levels that were obtained from pulmonary mixed venous blood have been compared to demonstrate the difference in the action mechanism of these drugs. METHODS Eighteen patients undergoing mitral or aortic and mitral valvular replacement with pulmonary hypertension >25 mmHg were included in the study. The 2 groups received iloprost or nitroglycerin via a central pulmonary catheter, and the hemodynamic parameters were evaluated before incision (T1), 10 minutes after chest opening (T2), and 5 minutes and 20 minutes after cardiopulmonary bypass (T3 and T4). The plasma nitric oxide levels were obtained from the mixed venous blood at the T1 and T4 intervals. RESULTS The data have been analyzed for each group and for repeated measurements of hemodynamic parameters at T1-T4 time points. The analysis of hemodynamic parameters before (T1 and T2) and after (T3 and T4) bypass showed similar responses depending on the use of either iloprost or nitroglycerin. The administration of iloprost after bypass (T3) at a dosage of 1.25 to 2.5 ng/kg per minute reduced mean pulmonary artery pressure (from 28.8 +/- 7.89 to 20.63 +/- 6.39 mmHg) and pulmonary vascular resistance (from 226.88 +/- 101.93 to 118.00 +/- 82.36 dyn sec cm -5) better than nitroglycerin at a dosage of 0.5 to 1 microg/kg per minute (from 23.20 +/- 5.20 to 18.50 +/- 5.10 mmHg and from 160.80 +/- 39.76 to 137.40 +/- 56.54 dyn sec cm -5, respectively). Iloprost causes significant increase in cardiac output (from 4.91 +/- 0.91 to 5.49 +/- 0.91 L/min) compared to nitroglycerin (from 5.23 +/- 0.80 to 5.27 +/- 0.74 L/min). The plasma nitric oxide levels of the iloprost group did not show an increase from T1 to T4, whereas the nitroglycerin group levels did (P <.05). CONCLUSIONS Intravenous use of both iloprost and nitroglycerin effectively reduces mean pulmonary artery pressure, although only the iloprost group was accompanied by an increase in cardiac output. During operation, where abrupt management of pulmonary hypertension is required, systemic use of iloprost or nitroglycerin at appropriate doses via a pulmonary artery catheter offers adequate relief of hypertension and is well tolerated without any significant adverse effects. The plasma nitric oxide levels did not rise with the use of iloprost.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

General anesthesia with remifentanil for cesarean section in a parturient with severe mitral and tricuspid regurgitation

Valvular heart lesions have deleterious effects on hemodynamics in parturients during pregnancy. Cesarean section with an opioid-based general anesthesia is used to alleviate the adverse effects. We described a case of a 28-year-old primigravida at 37 weeks’ gestation with a diagnosis of severe mitral regurgitation, tricuspid regurgitation, and pulmonary hypertension in active labor. Cesarean s...

متن کامل

A comparison of the acute hemodynamic effects of inhaled nitroglycerin and iloprost in patients with pulmonary hypertension undergoing mitral valve surgery.

BACKGROUND Since the presence of pulmonary hypertension (PHT) affects the prognosis of the patients, it is important to manage and evaluate PHT. The aim of this study was to compare the hemodynamic effects of inhaled nitroglycerin and iloprost during early postoperative period, in patients with PHT undergoing mitral valve replacement surgery. MATERIALS AND METHODS One hundred patients with PH...

متن کامل

Comparison of acute hemodynamic effects of aerosolized and intravenous iloprost in secondary pulmonary hypertension in children with congenital heart disease.

Both aerosolized and intravenous infusion of iloprost caused a significant decrease in mean pulmonary artery pressure and pulmonary vascular resistance. Although intravenous infusion caused a large decrease in mean systemic arterial pressure, this was only slightly affected by aerosolized iloprost. Aerosolized iloprost caused a significant decrease in the pulmonary-to-systemic vascular resistan...

متن کامل

Iloprost relaxes phenylephrine-precontracted rat aortic rings

Iloprost is a prostacyclin analogue mainly used in the treatment of pulmonary hypertension. It is also effective for renal dysfunction during renal transplant and coronary artery bypass grafting surgery, but there have been few comparative experimental studies with iloprost. We aimed to compare vasorelaxant properties of iloprost, with those of diltiazem, nitroglycerin and papaverine on rat tho...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The heart surgery forum

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2006