Health Condition Monitoring of Induction Motors

نویسندگان

  • Wilson Wang
  • Derek Dezhi Li
چکیده

Induction motors (IMs) are commonly used in various industrial applications. A spectrum synch (SS) technique is proposed in this chapter for early IM defect detection using electric current signals; fault detection in this work will focus on defects in rolling element bearings and rotor bars, which together account for more than half of IM imperfections. In bearing fault detection, the proposed SS technique will highlight the peakedness of the fault frequency components distributed over several fault related local bands. These bands are synchronized to form a fault information spectrum to accentuate fault features. A central kurtosis indicator is proposed to extract representative features from the fault information spectrum and formulate a fault index for incipient IM fault diagnosis. The effectiveness of the developed SS technique is tested on IMs with broken rotor bars and with damaged bearings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Embedded System for Online Monitoring of Induction Motors

Induction machines play a important role in industry and there is a demand for their reliable and safe operation. Different failures occurs in induction machines gives excessive down times and generate large losses in term, and this motivates the condition monitoring of induction motors. The condition monitoring includes taking measurements on three phase induction motor when it is operating in...

متن کامل

Elsevier Editorial System(tm) for Expert Systems With Applications Manuscript Draft Manuscript Number: ESWA-D-13-03076R1 Title: Condition monitoring of induction motors: a review and an application of an ensemble of hybrid intelligent models

In this paper, a review on condition monitoring of induction motors is first presented. Then, an ensemble of hybrid intelligent models that is useful for condition monitoring of induction motors is proposed. The review covers two parts, i.e., (i) a total of nine commonly used condition monitoring methods of induction motors; and (ii) intelligent learning models for condition monitoring of induc...

متن کامل

Condition monitoring of induction motors: A review and an application of an ensemble of hybrid intelligent models

In this paper, a review on condition monitoring of induction motors is first presented. Then, an ensemble of hybrid intelligent models that is useful for condition monitoring of induction motors is proposed. The review covers two parts, i.e., (i) a total of nine commonly used condition monitoring methods of induction motors; and (ii) intelligent learning models for condition monitoring of induc...

متن کامل

Detection of broken rotor bars in three-phase squirrel-cage induction motor using fast Fourier transform

Induction motors have become the most used electrical motors in the world. They are rugged, easy to maintain, low in cost and good in performance. Those benefits have made induction motors very popular among users. During their exploitation period induction motors are exposed to various stresses that can become fatal to their performance and bring with them huge economic losses and safety risks...

متن کامل

The Decision Making System for Condition Monitoring of Induction Motors Based on Vector Control Model

Induction motors are mainly used for variable load applications and it is vital to have a condition monitoring system with capabilities to diagnose motor faults in variable load conditions. The environment noise varies has non-linear relation with motor load and it challenges the decision making capability of the condition monitoring system. This paper addresses the issue of reliable decision m...

متن کامل

Health Monitoring Techniques of Induction Motor: An Overview

Induction motor is singly excited motor, which is very simple, compact and extremely rugged in construction and most reliable and low cost motor. Although, these motors are reliable but often exposed to hostile environments during its operation which results to early deterioration and in turn lead to the motors failure. Faults and failures of induction machines can lead to excessive downtimes a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017