Use of the Nexfin™ device to detect acute arterial pressure variations during anaesthesia induction.
نویسندگان
چکیده
BACKGROUND Standard non-invasive arterial pressure (AP) measurements are discontinuous. By providing non-invasive beat-to-beat AP measurements, Nexfin™ might limit duration of intraoperative hypotension and hypertension. We assessed the ability of Nexfin™ to detect AP variations by comparing its trending ability with invasive AP monitoring. METHODS Thirty-one subjects undergoing elective surgery under general anaesthesia were included. During induction, simultaneous pairs of AP measurements were collected every 5 s from the Nexfin™ finger sensor and a homolateral radial artery catheter. Magnitude and time lags of AP variations from baseline to nadir and peak were calculated for both methods. Concordance analysis was performed by the Bland-Altman method (for comparison of repeated measures when appropriate). RESULTS Nexfin™ detected 100% of AP changes with the median delays of 0 s (-13 to 7) and 0 s (-5 to 12) for nadir and peak, respectively. Bias [limits of agreement (LOA)] of systolic AP (SAP) variations was -0.5 mm Hg (-31.2 to 30.2) and -9.4 mm Hg (-31.3 to 12.6) from baseline to nadir and from baseline to peak, respectively. For 3479 analysed paired measurements, bias was -3.8 and -8.8 mm Hg for SAP and diastolic AP, with LOA of (-36.0 to 28.5) and (-29.8 to 12.3), respectively. CONCLUSIONS Nexfin™ detects AP variations accurately and can be a useful warning device during anaesthesia. However, it is not interchangeable with invasive monitoring, given the large LOA between the two measurements. CLINICAL TRIAL REGISTRATION NCT01658631.
منابع مشابه
Use of the NexfinTM device to detect acute arterial pressure variations during anaesthesia induction
Editor’s key points † Continuous measurement of beat-to-beat arterial pressure (AP) during the dynamic phases of anaesthesia facilitates recognition and treatment of acute variations. † The non-invasive AP monitor NexfinTM was compared with invasive AP (IAP) measurements during induction of anaesthesia. † NexfinTM reliably and quickly detected acute changes in AP, but its accuracy was insuffici...
متن کاملCARDIOVASCULAR Use of the NexfinTM device to detect acute arterial pressure variations during anaesthesia induction
Editor’s key points † Continuous measurement of beat-to-beat arterial pressure (AP) during the dynamic phases of anaesthesia facilitates recognition and treatment of acute variations. † The non-invasive AP monitor NexfinTM was compared with invasive AP (IAP) measurements during induction of anaesthesia. † NexfinTM reliably and quickly detected acute changes in AP, but its accuracy was insuffici...
متن کاملNon-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery.
BACKGROUND This observational study was designed to evaluate the reliability and precision of a new digital photoplethysmographic device (Nexfin, BMEYE B.V., Amsterdam, The Netherlands) for continuous and non-invasive assessment of arterial pressure and cardiac output. METHODS Fifty consecutive adult subjects were prospectively enrolled at admission to the intensive care unit after convention...
متن کاملContinuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.
BACKGROUND Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin™ device. We assessed the adequacy of a prototype device (Nexfin-paediatric), designed for a paediatric population, for...
متن کاملLevel of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children.
BACKGROUND We compared Nexfin non-invasive arterial pressure measurements using a novel small finger cuff with intra-arterial pressure in the paediatric setting in order to establish the level of agreement between both methods. METHODS The study included 41 children aged 2-16 yr admitted for surgery or paediatric intensive care with an intra-arterial catheter as part of standard monitoring. V...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 113 1 شماره
صفحات -
تاریخ انتشار 2014