Prior-regularized GRAPPA Reconstruction

نویسنده

  • F-H. Lin
چکیده

F-H. Lin Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States Introduction An auto-calibration scan (ACS) can help to improve the reconstructions in k-space based parallel MRI, such as GRAPPA [1]. Usually ACS is acquired at the center of k-space for higher SNR, thus constituting of full-FOV low-resolution prior images in the channels of an RF coil array. Previously, we have demonstrated the incorporation of prior information in SENSE imaging reconstruction to reduce noise amplification in both anatomical and functional scans [2, 3]. Based on a similar rationale, the incorporation of credible prior information may also improve GRAPPA reconstruction. Here we derive a robust prior-informed GRAPPA reconstruction based on the prior obtained from ACS. Formulated as Tikhonov regularization, the prior-informed GRAPPA is demonstrated to provide reduced aliasing artifact and noise level in the reconstruction compared with an unregularized one. Methods GRAPPA reconstruction can be formulated as a two-step algorithm. First the reconstruction coefficient β is solved using auto-calibration scan data (yacs) and actual acceleration data (Yacc), where yacs=Yaccβ. Second, based on the least-square fits for β and the actual accelerated data, the reconstruction of skipped data (yGRAPPA) is estimated: yGRAPPA=Yaccβ. In fact, the GRAPPA reconstruction can be regarded as applying a data-driven “inverse operator” Yacc on β. This corresponds to a forward problem of A yGRAPPA=β, where A=(Yacc). Given this forward problem, we can apply Tikhonov regularization to solve the prior-informed GRAPPA by minimizing the following cost function: |A yGRAPPA -β|+λ|yGRAPPAyGRAPPA|2, where yGRAPPA 0 is the prior and λ is the regularization parameter. In vivo anatomical images were acquired using a 3T scanner (Siemens Medical Solution, Erlangen, Germany) with an 8-channel phased array coil. We used a 3D MPRAGE sequence on a healthy subject after the approval from the Institutional Review Board and informed consent. Parameters of the MPRAGE sequence were TR=500 ms, TE=3.9 ms, flip angle=20 deg, slice thickness=3 mm with 1.5 mm gap, 48 slices, FOV=210 mm x 210 mm, image matrix=256 X 256. The same scan was repeated with the reduced number of phase encoding by 4-fold with 32 ACS lines. We calculated both regularized an unregularized GRAPPA images to compare the quality of the reconstructions. Results and Discussion The figure at left shows the fully sampled data and the low-resolution prior image with 32 ACS lines acquired from the center of k-space (effective acceleration: 2.91). It also shows both the unregularized and regularized reconstructions. Note that using regularization, the residual aliasing was reduced compared with the unregularized reconstruction (indicated by the blue arrows). The figure below shows the magnified temporal lobe (area indicated by the red box) for regularized and unregularized reconstruction. We found that the noise level was reduced in the deep brain areas, where coil information is less independent among channels. Quantitatively, the mean sum-of-square error for unregularized and regularized GRAPPA reconstructions with respect to the fully sampled data was 2.4% and 2.2%, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TV Regularization for High-Pass GRAPPA with Higher Net Acceleration Factor

Introduction In this work, a novel method using calculated calibration signal is introduced to improve high-pass GRAPPA (hp-GRAPPA) [1] when only limited auto-calibration signal (ACS) lines are acquired. Hp-GRAPPA suppresses the central calibration signal to reduce image support. When the number of ACS lines is limited, this suppression will result in insufficient calibration signal which cause...

متن کامل

TV Regularization for Segmented GRAPPA with Higher Net Acceleration Factor

Introduction In this work, we propose a novel method to apply segmented GRAPPA [1, 2] when only limited auto-calibration signal (ACS) lines are available. As pointed out in [3], segmented GRAPPA is superior to GRAPPA [4] but requires significant amount of ACS lines. To overcome this drawback, a total variation (TV) regularized GRAPPA technique is used to produce a full calibration k-space with ...

متن کامل

Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold.

PURPOSE To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. METHODS Saturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was u...

متن کامل

Generalized autocalibrating partially parallel acquisitions (GRAPPA).

In this study, a novel partially parallel acquisition (PPA) method is presented which can be used to accelerate image acquisition using an RF coil array for spatial encoding. This technique, GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) is an extension of both the PILS and VD-AUTO-SMASH reconstruction techniques. As in those previous methods, a detailed, highly accurate R...

متن کامل

Improving image quality in low snr parallel acquisition using a weighted least squares GRAPPA reconstruction

Introduction The generalized autocalibrating partially parallel acquisition (GRAPPA) [1] is a coilby-coil parallel image reconstruction that estimates missing data in k-space based on additionally acquired calibration lines. In GRAPPA reconstruction, the missing k-space is obtained by fitting the reduced data set to the autocalibration signals (ACS), acquired at Nyquist rate. This fitting proce...

متن کامل