Automated estimation of number of implanted iodine-125 seeds for prostate brachytherapy based on two-view analysis of pelvic radiographs

نویسندگان

  • Hidemichi Kawata
  • Hidetaka Arimura
  • Hiroaki Suefuji
  • Sunao Ohkura
  • Yoshifumi Saida
  • Kazutaka Nashiki
  • Kazuya Hayashida
  • Tomomi Kawahara
  • Ayumu Ohishi
  • Naofumi Hayabuchi
چکیده

Digital pelvic radiographs are used to identify the locations of implanted iodine-125 seeds and their numbers after insertion. However, it is difficult and laborious to visually identify and count all implanted seeds on the pelvic radiographs within a short time. Therefore, our purpose in this research was to develop an automated method for estimation of the number of implanted seeds based on two-view analysis of pelvic radiographs. First, the images of the seed candidates on the pelvic image were enhanced using a difference of Gaussian filter, and were identified by binarizing the enhanced image with a threshold value determined by multiple-gray level thresholding. Second, a simple rule-base method using ten image features was applied for false positive removal. Third, the candidates for the likely number of a multiply overlapping seed region, which may include one or more seeds, were estimated by a seed area histogram analysis and calculation of the probability of the likely number of overlapping seeds. As a result, the proposed method detected 99.9% of implanted seeds with 0.71 false positives per image on average in a test for training cases, and 99.2% with 0.32 false positives in a validation test. Moreover, the number of implanted seeds was estimated correctly at an overall recognition rate of 100% in the validation test using the proposed method. Therefore, the verification time for the number of implanted seeds could be reduced by the provision of several candidates for the likely number of seeds.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seed migration after transperineal interstitial prostate brachytherapy by using loose seeds: Japanese prostate cancer outcome study of permanent iodine-125 seed implantation (J-POPS) multi-institutional cohort study

BACKGROUND The incidence and associated factors of loose seed migration were investigated in cohort 1 of the Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation (J-POPS). METHODS The study subjects were 2160 patients, consisting of 1641 patients who underwent permanent iodine-125 seed implantation (PI) and 519 patients who underwent PI combined with external beam ...

متن کامل

Incidence of seed migration to the chest, abdomen, and pelvis after transperineal interstitial prostate brachytherapy with loose 125I seeds

BACKGROUND The aim was to determine the incidence of seed migration not only to the chest, but also to the abdomen and pelvis after transperineal interstitial prostate brachytherapy with loose (125)I seeds. METHODS We reviewed the records of 267 patients who underwent prostate brachytherapy with loose (125)I seeds. After seed implantation, orthogonal chest radiographs, an abdominal radiograph...

متن کامل

C-arm Pose Estimation in Prostate Brachytherapy by Registration to Ultrasound

In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be seen in C-arm fluoroscopy. Intra-operative dosimetry optimization requires reconstruction of the implanted seeds from multiple C-arm fluoroscopy images, which in turn requires estimation of the C-arm poses. We estimate the pose of the C-arm by two-stage registration between th...

متن کامل

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

متن کامل

An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy

Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 53  شماره 

صفحات  -

تاریخ انتشار 2012