Note: Detection of a single cobalt microparticle with a microfabricated atomic magnetometer.

نویسندگان

  • D Maser
  • S Pandey
  • H Ring
  • M P Ledbetter
  • S Knappe
  • J Kitching
  • D Budker
چکیده

We present magnetic detection of a single, 2 μm diameter cobalt microparticle using an atomic magnetometer based on a microfabricated vapor cell. These results represent an improvement by a factor of 10(5) in terms of the detected magnetic moment over previous work using atomic magnetometers to detect magnetic microparticles. The improved sensitivity is due largely to the use of small vapor cells. In an optimized setup, we predict detection limits of 0.17 μm(3).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zero-field remote detection of NMR with a microfabricated atomic magnetometer.

We demonstrate remote detection of nuclear magnetic resonance (NMR) with a microchip sensor consisting of a microfluidic channel and a microfabricated vapor cell (the heart of an atomic magnetometer). Detection occurs at zero magnetic field, which allows operation of the magnetometer in the spin-exchange relaxation-free (SERF) regime and increases the proximity of sensor and sample by eliminati...

متن کامل

Femtotesla atomic magnetometry in a microfabricated vapor cell.

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly pol...

متن کامل

Subpicotesla atomic magnetometry with a microfabricated vapour cell

Highly sensitive magnetometers capable of measuring magnetic fields below 1 pT have an impact on areas as diverse as geophysical surveying, the detection of unexploded ordinance, space science, nuclear magnetic resonance, health care and perimeter and remote monitoring. Recently, it has been shown that laboratory optical magnetometers, based on the precession of the spins of alkali atoms in the...

متن کامل

Impedance Based Microparticle Counter on an Interdigitated Electrode (ide) Surface with Single-bead Sensitivity

An interdigitated electrode (IDE) array-based impedance sensor is developed for microparticle detection. The IDE is fabricated by photolithography, Ti/Au deposition, and dielectric deposition. With this microfabricated IDE array, we demonstrated a highly portable impedance sensing system with frequency analyzing circuits, DAQ, and LabVIEW. With samples containing various microparticle concentra...

متن کامل

Chip - Scale Room - Temperature Atomic Magnetometers for Biomedical Measurements

We describe a portable four-channel array of chip-scale atomic magnetometers in a flexible flying-lead configuration. These microfabricated, uncooled sensors with volumes below 1 cm 3 demonstrate sensitivities around 100 fT/Hz 1/2 and bandwidths of several hundred hertz. Performance limits are discussed, as the design is easily scalable to different sensor sizes and large arrays. Initial measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 8  شماره 

صفحات  -

تاریخ انتشار 2011