Stroboscopic fluorescence lifetime imaging.

نویسندگان

  • Mark D Holton
  • Oscar R Silvestre
  • Rachel J Errington
  • Paul J Smith
  • Daniel R Matthews
  • Paul Rees
  • Huw D Summers
چکیده

We report a fluorescence lifetime imaging technique that uses the time integrated response to a periodic optical excitation, eliminating the need for time resolution in detection. A Dirac pulse train of variable period is used to probe the frequency response of the total fluorescence per pulse leading to a frequency roll-off that is dependent on the relaxation rate of the fluorophores. The technique is validated by demonstrating wide-field, realtime, lifetime imaging of the endocytosis of inorganic quantum dots by a cancer cell line. Surface charging of the dots in the intra-cellular environment produces a switch in the fluorescence lifetime from approximately 40 ns to < 10 ns. A temporal resolution of half the excitation period is possible which in this instance is 15 ns. This stroboscopic technique offers lifetime based imaging at video rates with standard CCD cameras and has application in probing millisecond cell dynamics and in high throughput imaging assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stroboscopic illumination using light-emitting diodes reduces phototoxicity in fluorescence cell imaging.

Excited fluorophores produce reactive oxygen species that are toxic toward many live cells (phototoxicity) and accelerate bleaching of the fluorophores during the course of extended or repeated measurements (photobleaching). We recently developed an illumination system for fluorescence microscopy using a high power light-emitting diode (LED), which can emit short pulses of light (0.5-2 ms) to e...

متن کامل

Fluorescence lifetime imaging ophthalmoscopy

Imaging techniques based on retinal autofluorescence have found broad applications in ophthalmology because they are extremely sensitive and noninvasive. Conventional fundus autofluorescence imaging measures fluorescence intensity of endogenous retinal fluorophores. It mainly derives its signal from lipofuscin at the level of the retinal pigment epithelium. Fundus autofluorescence, however, can...

متن کامل

Technique for measurement of fluorescence lifetime by use of stroboscopic excitation and continuous-wave detection.

A study of the practicality a simple technique for obtaining time-domain information that uses continuous wave detection of fluorescence is presented. We show that this technique has potential for use in assays for which a change in the lifetime of an indicator occurs in reaction to an analyte, in fluorescence resonance energy transfer, for example, and could be particularly important when one ...

متن کامل

Timing and Operating Mode Design for Time-Gated Fluorescence Lifetime Imaging Microscopy

Steady-state fluorence imaging and time-resolved fluorescence imaging are two important areas in fluorescence imaging research. Fluorescence lifetime imaging is an absolute measurement method which is independent of excitation laser intensity, fluorophore concentration, and photobleaching compared to fluorescence intensity imaging techniques. Time-gated fluorescence lifetime imaging microscopy ...

متن کامل

Fluorescence-lifetime molecular imaging can detect invisible peritoneal ovarian tumors in bloody ascites

Blood contamination, such as bloody ascites or hemorrhages during surgery, is a potential hazard for clinical application of fluorescence imaging. In order to overcome this problem, we investigate if fluorescence-lifetime imaging helps to overcome this problem. Samples were prepared at concentrations ranging 0.3-2.4 μm and mixed with 0-10% of blood. Fluorescence intensities and lifetimes of sam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2009