A 7.36 nm soft x-ray laser pumped in double-pulse single beam grazing incidence (DGRIP)

نویسندگان

  • D. Zimmer
  • D. Ros
  • V. Bagnoud
  • B. Ecker
  • O. Guilbaud
  • J. Habib
  • D. Hochhaus
  • S. Kazamias
  • B. Zielbauer
  • B. Aurand
  • P. Neumayer
  • T. Kuehl
چکیده

D. Zimmer∗1,2,3, D. Ros1, V. Bagnoud2, B. Ecker2,3, O. Guilbaud1, J. Habib1, D. Hochhaus2,3, S. Kazamias1, B. Zielbauer1,2, B. Aurand2,3, P. Neumayer2, and T. Kuehl2,3 1LASERIX-CLUPS, LIXAM UMR 8624, Université Paris-Sud 11, Bât. 350, F-91405 Orsay Cedex, France; 2GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt, Germany; 3Institut für Physik, Johannes Gutenberg-Universität Mainz, Staudingerweg 7, D-55128 Mainz, Germany

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Table-top high repetition rate soft x-ray laser pumped in double-pulse single beam grazing incidence (DGRIP)

D. Zimmer∗1,2,3, B. Zielbauer1,2, M. Pittman1, O. Guilbaud1, J. Habib1, S. Kazamias1, D. Ros1, V. Bagnoud2, B. Ecker2,3, D. Hochhaus2,3, and T. Kuehl2,3 1LASERIX-CLUPS, LIXAM UMR 8624, Université Paris-Sud 11, Bât. 350, F-91405 Orsay Cedex, France; 2GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt, Germany; 3Institut für Physik, Johannes Gutenberg-Universität ...

متن کامل

Spatial coherence measurements of a 13.2 nm transient nickel-like cadmium soft x-ray laser pumped at grazing incidence.

The spatial coherence of a 13.2 nm transient collisional Ni-like Cd soft X-ray laser pumped at 23 degrees grazing incidence was measured in a series of Young's double-slit experiments. We observed pronounced fringe visibility variations associated with microstructures in the beam's intensity profile. The transverse coherence length was measured to be about 1/20 of the beam diameter and did not ...

متن کامل

Characterization of a 10Hz double-pulse non-normal incidence pumped transient collisional Ni-like molybdenum soft x-ray laser for applications

Stable and reliable operation demonstrated and studied with a 10 Hz Ti:sapphire laser system proves the suitability of the double-pulse non-normal incidence pumping geometry for table-top high repetition soft x-ray lasers (SXRL) on the way to applications. In this experiment a nickel-like molybdenum 4d1S0 − 4p1P1 transient collisional soft X-ray laser at 18.9 nm is investigated which is pumped ...

متن کامل

A 10 Hz, 3 microjoule transient soft X-ray laser pumped in grazing incidence

We present recent results on the extensive investigation of a Ni-like Mo X-ray laser pumped in the transient regime and GRIP (grazing incidence pumping) configuration. The pump laser was the 10 Hz, multi-terawatt, Ti:Sa laser system at Lund Laser Centre, Sweden. The main diagnostic was a monochromatic near-field imaging system with a 1.7 micron spatial resolution. Intense lasing was observed ro...

متن کامل

Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers.

We have measured the pulse duration of gain-saturated 13.9 nm Ni-like Ag and 13.2 nm Ni-like Cd transient collisional lasers excited by grazing-incidence-pumping for several pumping conditions. High-resolution streak-camera measurements yielded FWHM pulse durations close to 5 ps for both lasers under optimum pumping conditions. The very high brightness and short pulse duration of these new high...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010