Acoustic emission (AE) technique is gaining increasing interest for application in civil engineering. AE indeed is a passive non intrusive technique that can be applicable either in Structural Health Monitoring SHM (global evaluation) and in defect localization (local evaluation). However a great effort yet have to be done on data handling and data interpretation, especially in eliminating acoustic noise generated, for example, by not structurally significant concrete micro-cracking under loading condition. Some interesting results in AE analysis can be obtained by applying relationships already applied in earthquake seismology and in rock fracture studies. Aim of the present work was to assess the capability of the band Ib-value analysis, to evaluate damage condition of concrete structures. AE monitoring was used during proof loading of two seriously damaged viaduct. The analysis of the temporal variation of b value as well as the analysis of the acoustic quiescence was also performed with promising results. Résumé La technique de l'émission acoustique (AE) est de plus en plus intéressante pour l'application en génie civil. L'AE est en effet une technique passive et non intrusive qui peut être appliquée soit en surveillance de la santé des structures SHM (évaluation globale) soit pour la localisation des défauts (évaluation locale). Toutefois, un grand effort est encore à fournir sur le traitement et l'interprétation des données, en particulier dans l'élimination du bruit acoustique généré, par exemple, celui émis par les micro-fissurations qui ne sont pas structurellement importantes sous condition de chargement. Des résultats intéressants en analyse de l'AE peuvent être obtenus par l'application de relations déjà utilisées en sismologie, dans l'étude de tremblement de terre et dans les études des fractures de la roche. L'objectif de ce travail est d'évaluer la capacité de l'analyse des valeurs b et Ib, afin d'évaluer les désordres des structures en béton. L'AE suivi a été utilisé au cours des essais de chargement des deux viaducs gravement endommagés. En outre l'analyse de la variation temporelle de la valeur b, ainsi que l'analyse de l' inactivité acoustique a également été effectuée avec des résultats prometteurs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Damage Detection in Post-tensioned Slab Using 2D Wavelet Transforms

Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...

متن کامل

Experimental Study and Modeling of Reinforced Concrete Beams Strengthened by Post-Tensioned External Reinforcing Bars

The utilization of unbounded external reinforcing bars is one of the strengthening methods used after loading stage and before failure. The method has been used in different forms to strengthen members of reinforced concrete structures. To investigate the effect of utilization of post-tensioned reinforcing bars in this method of strengthening, a number of reinforced concrete beams was tested. S...

متن کامل

Ultimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs

Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...

متن کامل

Ultimate Tendon Stress in CFRP Strengthened Unbounded HSC Post-Tensioned Continuous I-Beams

The use of unbounded tendons is common in prestressed concrete structures and evaluation of the stress increase in unbonded tendons at ultimate flexural strength of such structure has posed a great challenge over the years. Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the monitoring of the stress increment ...

متن کامل

Flexural Strengthening of Deficient Reinforced Concrete Beams with Post-Tensioned Carbon Composites using Finite Element Modelling

The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009