Comparison of blood gas and electrolyte test results from the Gem-Stat and CDI-300 versus a conventional laboratory analyzer.

نویسندگان

  • H G Walton
  • T B Duvall
  • J Van den Hout
  • D M Boucher
چکیده

Continuous blood gas monitoring devices have been an aid to the perfusionist since the introduction of the oxygen saturation meters of the early 1980s. Since that time, the perfusionist has had to decide between continuous versus intermittent sampling, and on-line (an analyzer that can automatically sample either at prescribed intervals and/or on demand) versus in-line devices (monitors that continuously sample and display results). This report compares the continuous, in-line CDI-300 blood gas monitor and the Mallinckrodt Gem-Stat blood gas analyzer using intermittent sampling with the Corning 278 blood gas analyzer and 2500 Co-Oximeter. Thirty samples were taken, one per 30 patients, for comparison. Five samples were disqualified from the study. When comparing the remaining 25, the Gem-Stat results to the Corning 278 blood gas analyzer results, all measured values (arterial pH, pCO 2, pO 2, venous pO 2, Na, K and Hct) correlated greater than 0.5000 with a p value of less than 0.001. The exception was the ionized calcium value which had a correlation of 0.2473 with a p value of less than 0.232. When comparing the CDI-300 results to the Corning 278 blood gas machine results, all measured values (pH, pO 2, pCO 2, and venous pO 2) correlated greater than 0.5000 with a p value of less than 0.003 or better. When comparing the Gem-Stat results to the CDI results, all measured values (pH, pCO 2, pO 2 and venous pO 2) correlated greater than 0.5000 with a p value of less than 0.002 or better.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of blood gas and electrolyte test results from the Gem-Premier and the ABL-70 versus a conventional laboratory analyzer.

Blood gas analyzers serve a critical role in providing information that reflects patient homeostasis. This study was undertaken to evaluate the accuracy, reliability, consistency, and bias of the Radiometer ABL-70 point of care blood gas analyzer. Thirty samples were gathered for analysis of pH, pCO2, pO2, sodium, potassium, sodium bicarbonate, and base excess. Twenty-nine samples were gathered...

متن کامل

Performance of Gem Premier blood gas/electrolyte analyzer evaluated.

We evaluated a new analyzer designed for point-of-care testing of blood gases, sodium, potassium, ionized calcium, and hematocrit. The Gem Premier (Mallinckrodt) system has two components: the analyzer and a disposable cartridge. Analysis takes place in the cartridge, which contains the electrochemical sensors, the calibrants, the reagents, the sampling stylus, and the waste container. The syst...

متن کامل

Evaluation of the Enterprise Point-of-Care (EPOC) System for Blood Gas and Electrolyte Analysis

Objective: To evaluate the analytical performance of a new point-ofcare blood gas and electrolyte analyzer, the EPOC system. Materials and Methods: Evaluation of analytical precision and method comparison was conducted at the manufacturing facilities and at several locations in a 630-bed tertiary acute care hospital in New England, an intensive care unit, cardiac intensive care unit, an outpati...

متن کامل

Reliability of the i‐STAT for the determination of blood electrolyte (K+, Na+, and CI −) concentrations in cattle

BACKGROUND Rapid determination of blood electrolyte concentrations can help determine electrolyte status and delivery of effective volume of electrolyte solutions in field conditions. OBJECTIVE To evaluate reliability of the i-STAT, a point-of-care (POC) device, in measuring blood K(+), Na(+), and CI(-) concentrations in cattle. ANIMALS Ninety-eight cattle with various diseases. METHODS I...

متن کامل

The accuracy and timeliness of a Point Of Care lactate measurement in patients with Sepsis

BACKGROUND The aims of this study were to a) compare the lactate measurement of a Point of Care (POC) handheld device to near patient blood gas analysers, and b) determine the differential reporting times between the analysers. METHODS A two-staged study; method comparison and prospective observational stages, was conducted. For the first stage, blood samples were analysed on the i-STAT handh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1993