Performance Evaluation and Myths regarding Radon Analysis via E-perms: Actual Field

نویسندگان

  • Michael
  • Ferraro
چکیده

This paper reports field results of E-PERMS in both (lie S-Chamber and their keeper caps. Hie results have been compiled during the past two years covering over 5,000 measurements. Data has been grouped to show precision (co-located tests), accuracy (radon chamber results), and electret stability. The latter results were also broken down into S-Chamber versus keeper cap versus electret series. Besides the aforementioned, a major emphasis will be comparing on-site E-PERM data versus those E-PERMS mailed overnight throughout the country. Overall the data showed that the E-PERMS are accurate and very precise. However, with regard to electret stability, older series and physically older electrets within a series appear to be somewhat more stable or less sensitive than newer electrets. Nevertheless, there is no difference when comparing the results of E-PERMS measured on site versus those air mailed back and forth to the same analysis lab for measurement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MEASUREMENT OF ""Rn (THORON) USING ELECTRET ION CHAMBERS

Recently there has been an increased interest in the measurement of airborne ""Rn (thoron). Such measurements are particularly targeted in areas rich in thorium, and in facilities processing thorium compounds and associated radioactive wastes. Standard electret ion chambers @-PERMSR)* designed for making indoor and outdoor "^Rn (radon) measurement have very little response to "¡R (thoron). How...

متن کامل

Elevation Correction Factors K)r E-perm(r) Radon Monitors

E-PERM(R) radon monitors are based on the principle of electret ion chambers and these are usually calibrated in a standard radon chamber located at sea level. Corrections are needed if these are used in elevations other than sea level. These were experimentally determined for three models of commercially available electret ion chambers (E-PERMS(R)) as functions of elevation above sea level. . ...

متن کامل

The Occurrence of Radon on the Tobique First Nation Reserve and Its Implication for Radon Occurrence along the Saint John River Valley

A survey of 6 large public buildings on Tobique First Nation land in northern New Brunswick, showed five of them to be above the acceptable limit of 200 Bq/m. As most of the 350 homes on the Reserve are located close to any one of these buildings, the concerns generated by the test results, and resulting anxiety for radon in their own homes by residents, was high. This was fueled by the histori...

متن کامل

Field calibration of the glass-based retrospective radon detectors for epidemiologic applications

The primary goal of this PhD research was to obtain critical information needed to further calibrate the novel glass-based retrospective radon detectors (RRDs) by characterizing the quantitative relationship between radon gas concentrations, the surface-deposited activities of various radon progeny, the airborne dose rate, and various residential environmental factors through both actual field ...

متن کامل

Exploring Language Learners’ Cognitive Processes in On-line ESP Courses via Think-aloud Protocol Analysis

The present study aims to investigate language learners’ cognitive processes in on-line ESP courses. Three modes of inquiry are used: think-aloud protocol analysis, screen capture analysis, and correlation analysis. The theoretical foundations for the evaluation of the cognitive aspect of Ferdowsi Univeristy of Mashhad E-learning System are drawn from cognitive load theory, cognitive apprentice...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007